Waldorf PC8140G Installation And Operation Manual - page 21
Gas Conversion and Specifications
19
Gas Regulator
NOTE:
Gas regulator supplied is
convertible between Natural Gas
and LP Gas, but it’s outlet
pressure is fixed ex-factory and
is NOT to be adjusted.
Gas Type Labels
On completion of gas conversion, replace gas type labels located at:-
- Rear of unit, above gas connection.
- Beside rating plate.
Commissioning
Before leaving installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3.
Ensure any adjustments done to components that have adjustments / settings paint sealed are to be
re-sealed.
NOTE: If for some reason it is not possible to get appliance to operate correctly, shut Off gas
supply and contact supplier of this appliance.
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning