Waldorf RN8110G Installation And Operation Manual - page 20
18
Gas Conversion and Specifications
Static Oven
1.
Carry out the following:-
Remove lower lintel at front of oven.
Open oven door and remove sole plate(s).
Remove main burner.
Disconnect pilot supply tube from pilot burner
to access pilot injector.
2.
With Main Burner removed, ensure aeration gap is adjusted
for type of gas being used as shown in ‘Gas Specifications
Tables’ at end of this section.
3.
Remove pilot and main injectors and replace with correct
size injectors as shown in ‘Gas Specifications Tables’ at end
of this section.
4.
Refit the following:-
Re-connect pilot supply tube to pilot burner.
Refit main burner and sole plate(s).
Refit lower lintel.
5.
To replace low fire screw in static oven gas valve:-
Remove oven control panel.
Remove low fire screw from gas valve and replace with
correct size low fire screw as shown in ‘Gas Specifications
Tables’ at end of this section.
NOTE: The 'Low Fire Screw' should be sealed with coloured
paint on completion of low fire adjustment.
Refit oven control panel.
Gas Regulator
NOTE: The gas regulator supplied is
convertible between Natural
Gas and LP Gas, but it’s outlet
pressure is fixed ex-factory
and is NOT to be adjusted.
Gas Type Identification Label
On completion of gas conversion, replace gas type identification label located at:-
- Rear of appliance, above gas connection.
- Beside the rating plate.
Commissioning
Before leaving the installation;
1.
Check all gas connections for leakage using soapy water or other gas detecting equipment.
2.
Carry out a ‘Commissioning’ check of appliance as shown in Installation Section of this manual.
3.
Ensure any paint sealed components are re-sealed on completion of adjustments.
Burner Adjustment Screw
Main Burner
Main Burner Injector
Pilot Burner
Thermocouple
Aeration Slide
Low Fire Adjustment Screw
NOTE, Pin rotated
for Natural Gas
NOTE, Pin rotated
for LPG
D
O
NOT
USE
A
NAKED
FLAME
TO
CHECK
FOR
GAS
LEAKAGES
.
Warning