Waldorf RN8110G Installation And Operation Manual - page 5
3
Specifications
Model Numbers Covered in this Specification
RN[1]8110G
Gas Target Top Range Static Oven.
NOTE:
[1]: - Back Options;
-
- Standard Models.
L
- Low Back Models.
General
A commercial heavy duty, general purpose fully modular, gas fired Target Top Range Static Oven, having a
high output, two stage double-ring iron cast burner offering accurate temperature control and infinitely
variable heat with the heat radiating out from the centre of the Target Top. The Main Burner is located
underneath removable cast target top plates.
The Target Top is uses a 45 MJ/hr burner and as standard is fitted with full pilot, flame failure protection.
The Oven utilizes a 30 MJ/hr oven main burner with pilot and flame failure protection and is fitted with
piezo ignition to the oven pilot burner. The oven is controlled with a 80 to 300ºC thermostat. Access to
the oven main and pilot burner is via a drop down door and a removable front lintel on the lower part of
the oven.
The appliance is built to facilitate easy cleaning and maintenance with all parts being front accessible once
the appliance is installed.
Gas Supply Requirements
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
1.
* Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to ‘Gas Conversion’ section for details).
Natural Gas
LP Gas (Propane)
Target Top
Oven
Target Top
Oven
Input Rate (N.H.G.C.)
45 MJ/hr
(42,650 Btu/hr)
30 MJ/hr
(28,435 Btu/hr)
45 MJ/hr
(42,650 Btu/hr)
30 MJ/hr
(28,435 Btu/hr)
Gas Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18” w.c.)
Burner Operating Pressure
1.0 kPa (*)
(4.0” w.c.)
2.60 kPa (*)
(10.0” w.c.)
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas (G20)
Propane (G31)
Target Top
Target Top
Heat Input (nett)
Nominal
11.5 kW
8.0 kW
11.5 kW
8.0 kW
Reduced
4.7 kW
2.4 kW
7.9 kW
2.4 kW
Gas Rate (nett)
Nominal
1.22 m
3
/hr
0.85 m
3
/hr
0.89 kg/hr
0.62 m
3
/hr
Reduced
0.50 m
3
/hr
0.25 m
3
/hr
0.61 kg/hr
0.19 m
3
/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure
9.9 mbar (*)
26.8 mbar (*)
Gas Connection
3
/
4
” B.S.P. Male
Oven
Oven