Waldorf RN8110G Installation And Operation Manual - page 21
19
Gas Conversion and Specifications
Gas Specifications
- Non CE Only (Australia / New Zealand):
- CE Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
1.
* Measure burner operating pressure at target top hob manifold test point with target top burner
(Inner and outer ring) operating at full setting. Operating pressure is ex-factory set through
appliance regulator and not to be adjusted, apart from when carrying out gas conversion, if
required. (Refer to details in this section for information).
Nat. Gas
LP Gas (Propane)
Target Top
Main Burner Injector (Inner Ring)
Ø 1.70 mm
Ø 1.10 mm
Main Burner Injector (Outer Ring)
Ø 2.60 mm
Ø 1.55 mm
Pilot Burner Injector
0.35
0.25
Burner Aeration Screw X (Inner)
25 mm
25 mm
Burner Aeration Screw Y (Outer)
28 mm
28 mm
Low Fire Adjustment
2½ turns out (ccw)
1 turn out (ccw)
Oven
Main Burner
Ø 2.60 mm
Ø 1.60 mm
Pilot Burner
0.35
0.23
Low Fire Screw
Ø 1.5 mm
Ø 0.95 mm
Burner Operating Pressure
1.00 kPa (*)
2.60 kPa (*)
Gas Regulator Cap Screw
Burner Aeration Setting
Fully Open
Fully Open
Natural Gas
(G20)
Propane
(G31)
Target Top
Main Burner Injector (Inner Ring)
Ø 1.70 mm
Ø 1.10 mm
Main Burner Injector (Outer Ring)
Ø 2.60 mm
Ø 1.55 mm
Pilot Burner Injector
0.35
0.25
Burner Aeration Screw X (Inner)
25 mm
20 mm
Burner Aeration Screw Y (Outer)
28 mm
25 mm
Low Fire Adjustment
2
1
/
2
turns out (ccw)
1¾ turn out (ccw)
Oven
Main Burner
Ø 2.60 mm
Ø 1.60 mm
Pilot Burner
0.35
0.23
Low Fire Screw
Ø 1.5 mm
Ø 0.95 mm
Operating Pressure
9.9 mbar (*)
26.8 mbar (*)
Gas Regulator Cap Screw
Burner Aeration Setting
Fully Open
Fully Open