WALKY WL1024 Instructions And Warnings For Installation And Use

Manual is about: Swing gate opener

Summary of WL1024

  • Page 1

    En - instructions and warnings for installation and use it - istruzioni ed avvertenze per linstallazione e luso fr - instructions et avertissements pour linstallation et lutilisation es - instrucciones y advertencias para la instalación y el uso de - installierungs-und gebrauchsanleitungen und hinwe...

  • Page 3: English

    En english – 1 english contents 1 - warnings and general precautions . . . . . . . . . . . . . . . . . . . . 1 1.1 - safety warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 - warnings for installation . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 4

    En 2 – english 3.1 - pre-installation checks before going ahead with the installation, check the integrity of the product com- ponents, and ensure the model chosen is suitable for its intended use and for the environment in which it is to be installed. • check that all the material to be used is in ...

  • Page 5

    En english – 3 3.4 - installation of the gearmotor mod. Wl1024c - wl1024 warnings • failure to install correctly can cause serious injury to the person carry- ing out the work and those using the system. • before starting to assemble the automation system, carry out the pre- liminary checks describe...

  • Page 6

    En 4 – english 3.4.3 - installation of a gearmotor with a shortened arm important! - this part of the installation can only be carried out after 3.4.1 has been completed. 01. Determine a new maximum opening angle for the gate leaf (max 90°): ignoring the maximum opening position established for the ...

  • Page 7

    En english – 5 the electrical connection of the various devices (photocells, digital keyboards, transponder card readers, etc.) of the automation system with a control unit is carried out with the nice “bluebus” system. This system makes it possible to carry out the electrical connections with the u...

  • Page 8

    En 6 – english control unit on terminals “p.P. (positive)” and “stop (negative)” (fig. 26). The supply voltage varies from 18 to 31 vdc when mains or solemyo operated and from 11 to approx. 14 vdc when operating on back-up battery ps424. The maximum available current is 200 ma. Note – the voltage av...

  • Page 9

    En english – 7 5.1 - testing the sequence of steps to take to carry out testing refers to a typical system (fig. 2): 1 release the gearmotors manually and check that when you operate the leaf, at the point designed especially for the manual manoeuvre, the leaves can either be opened or closed with a...

  • Page 10

    En 8 – english table 7 - level two programming procedure 01. Press and keep key “set” pressed for approximately 3 seconds; 02. Release the key when led “l1” begins to flash; 03. Press key “ ” or “” to move the flashing led to the led representing the “input led” of the parameter you wish to change; ...

  • Page 11

    En english – 9 some devices are designed to emit signals which help you recognise their operating status or any problems. If the wlt multi-purpose lamp is connected to the flash output on the power supply and set with the flashing function, during the performance of a manoeu- vre, it emits a flashin...

  • Page 12

    En 10 – english the following accessories are envisaged for walky (radio receiver): the oview programmer, the solemyo solar power system and the back-up battery mod. Ps424. 8.1 - connection of the oxi radio receiver to connect the oxi receiver, first cut off the electricity supply to the control uni...

  • Page 13

    En english – 11 disposing of the product this product is an integral part of the automation system, and should therefore be disposed of together with it. As for the installation operations, even at the end of this products life span, the dismantling operations must be carried out by qualified expert...

  • Page 14

    En 12 – english ec declaration of conformity note - the contents of this declaration correspond to the declarations contained in the latest available revision, prior to printing of this manual, of the official document on file at the headquarters of nice s.P.A. This text was readapted for editorial ...

  • Page 15: Appendix

    I en appendix • instructions and warnings for the user • images it appendice • istruzioni ed avvertenze destinate allutilizzatore • immagini fr appendice • instructions et recommandations destinées à lutilisateur • images es apéndice • instrucciones y advertencias destinadas al usuario • imágenes de...

  • Page 16

    En english – iii • if the automation system was secured with the command "secure automation system”: after a command is sent, the gate does not move and the flashing light emits 9 brief flashes. Securing and releasing the gearmotor manually the gearmotor is equipped with a mechanical system which al...

  • Page 17

    X 1 2 2 a 385 mm 125 mm 85 mm.

  • Page 18

    3 xi 6 7 4 5.

  • Page 19

    Xii 1 2 3 4 5 6 7 8 9 10 12 11 8.

  • Page 20: ~45°

    Xiii 1 2 3 4 ~45° ~45° 2 3 1 a c b ok ok b a 9 a a b 5 6 7 8 9 10 11 12 13.

  • Page 21

    Xiv 10 11 12 1 2 3 4.

  • Page 22

    Xv 15 2 1 4 3 2 1 14 16 2 1.

  • Page 23

    Xvi 2 3 4 1 17 2 1 4 6 3 5 18.

  • Page 24

    2 1 19 2 1 4 6 3 5 20 xvii.

  • Page 25

    8 7 9 10 21 1 2 3 5 6 xviii xviii.

  • Page 26: 11-A

    Xix 1 2 3 1 3 2 b a 22 7 8 9 10 11-a 11-b 12 13 14.

  • Page 27

    Xx 23 24 1 2 3 4 5 6.

  • Page 28

    Xxi 26 1 - en connector for battery / solemyo photovoltaic power • it connettore per batteria / alimentazione fotovoltaica so - lemyo • fr connecteur pour batterie / alimentation phovol ta - ï que solemyo • es conector para batería / ali men tación fo tovoltaica solemyo • de steckverbinder für batte...

  • Page 29

    Xxii xxii 1 2 3 4 5 6 28.

  • Page 30

    Xxiii xxiii 29 30 1 2 3 4 5 6.