TABLE 7 - Level two programming procedure
01. Press and keep key “Set” pressed for approximately 3 seconds;
02. Release the key when LED “L1” begins to flash;
03. Press key “
” or “” to move the flashing LED to the LED representing the “input LED” of the parameter you wish to change;
04. Press and keep pressed the “Set” key until step 06 is complete;
05. Wait approximately 3 seconds until the LED representing the current level of the parameter to be changed is turned on;
06. Press key “
” or “” to move the LED representing the value of the parameter;
07. Release the “Set” key;
08. Wait 10 seconds (maximum) to exit programming mode.
Note – To program several parameters when the procedure is in progress, repeat steps 03 to 07 during the phase itself.
L1
or
or
3 s
10 s
6.3 - Memory deletion
To delete the memory of the control unit and restore all the factory settings, pro-
ceed as follows: press and keep pressed keys “
” and “” until LEDs L1 and
L2 start to flash.
6.4 - Special functions
Function: “Move anyway”
This function makes it possible to operate the automation system even when a
safety device is not working properly or is out of order.
The automation system can be controlled in “push to run” mode as follows:
01. Send a command to operate the gate, using a transmitter or key selector,
etc. If everything is working properly, the gate will move normally, otherwise
proceed as follows:
02. within 3 seconds, send the command again and keep it activated;
03. after approximately 2 seconds, the gate will perform the manoeuvre
requested in “push to run” mode; i.e. the gate will continue to move only
for as long as the command is activated.
When the safety devices do not work, the flashing light emits a few flashes to
indicate the type of problem (see chapter 7 - Table 10).
TABLE 8 - Level two functions
LED
Parameter
LED
Value Description
input
(level)
L1
L1
L2
L3
L4
5 seconds
30 seconds
60 seconds
120 seconds
Adjusts the pause time, i.e. the amo -
unt of time before the gate closes au -
tomatically. Only effective is Close is
activated.
Pause
Time
L2
L1
L2
L3
L4
Opens – stop – closes – stop
Opens – stop – closes – opens
Opens – closes – opens – closes
Apartment building:
• during the opening manoeuvre, the “Step-Step” and “Opens” commands
do not have any effect; on the other hand, the “Closes” command causes
the movement to be inverted, i.e. the leaves to close.
• during the closing manoeuvre, the “Step-Step” and “Opens” commands
cause the movement to be inverted, i.e. the leaves to open; on the other
hand, the “Closes” command does not have any effect.
Adjusts the sequence of commands
associated with the “Step-Step” in -
put or radio command.
Note – When L4 is set, the behaviour
of the “Opens” and “Closes” comma -
n ds is also modified.
Step-Step
Function
L3
L1
L2
L3
L4
Slow
Medium
Fast
Very fast
Adjusts the velocity of the motors du -
ring normal travel.
Motor
velocity
L4
L1
L2
L3
L4
Level 1 - Minimum force
Level 2 - ...
Level 3 - ...
Level 4 - Maximum force
Adjusts the force of both motors.
Motor
force
6.2 - Level two programming (adjustable parameters)
All level two parameters are programmed at the factory as highlighted in grey in
Table 8 and can be modified at any time following the procedure described in
Table 7.
The parameters are adjustable on a scale of values from 1 to 4; to check the
value corresponding to each LED, please see Table 8. IMPORTANT –The pro-
gramming procedure has a maximum time of 10 seconds between one key and
another being pressed. After this time, the procedure ends automatically, stor-
ing the changes made up until that moment.