WALKY WL1024 Instructions And Warnings For Installation And Use - page 12
EN
10 – English
The following accessories are envisaged for WALKY (radio receiver): the Oview
programmer, the Solemyo solar power system and the back-up battery mod.
PS424.
8.1 - Connection of the OXI radio receiver
To connect the OXI receiver, first cut off the electricity supply to the control unit
and proceed as illustrated in fig. 27. Table 12 and Table 13 indicate the com-
mands which correspond to the outputs on the control unit.
8.2 - Connection and installation of the back-up battery
mod. PS424
IMPORTANT! - The battery must only be connected to the control unit
after all the phases of installation and programming have been complet-
ed, as the battery constitutes a source of emergency power.
To arrange connection to the Solemyo system, follow the stages of assembly
fig. 28.
8.3 - Connection of the Oview programmer
The control unit has a BusT4 connector to which the Oview programming unit
can be connect, and which allows the complete rapid management of the
installation and maintenance phase as well as the diagnosis of the entire
automation system. To access this connector, proceed as shown in fig. 29 and
connect the connector to the dedicated seat. The Oview can be connected to
several Control units simultaneously (up to 5 without any particular precautions,
and up to 60 observing the dedicated warnings) and can stay connected to the
control unit even during the normal operation of the automation system. In this
case, it can be used to send the commands directly tot he control unit using the
specific "user" menu. The Firmware upgrade can also be carried out. If there is
a radio receiver from the OXI family in the control unit, Oview can be used to
gain access to the parameters of the transmitters stored in the receiver itself.
For further information, please consult the relevant instruction manual and the
manual for the “Opera system book” system.
8.4 - Connection of the Solemyo solar power system
IMPORTANT! – When the automation system is powered by the “Sole-
myo” system, IT MUST NOT BE POWERED concurrently by the electricity
mains.
For further information about the Solemyo system, please refer to its instruction
manual.
To arrange connection to the Solemyo system, follow the stages of assembly
illustrated in fig. 30.
To complete the connection between Solemyo and the gearmotor control unit,
use the dedicated adapter cable.
FURTHER INFORMATION
8
1
Step-Step
2
Partial opening 1
3
Opens
4
Closes
5
Stop
6
Step-Step
Apartment Building
7
Step-Step
high priority
8
Partial opening 2
9
Partial opening 3
10
Opens and Secure
automation system
11
Closes and Secure
automation system
12
Secure automation
system
13
Release automation
system
14
On Timer Courtesy
Light
15
On-Off Courtesy
Light
TABLE 13
OXI / OXIFM /OXIT / OXITFM in mode II extended
No.
Command
Description
Command “P.P.” (Step-Step)
Command “partial opening 1”
Command “Opens”
Command “Closes”
Stop the manoeuvre
Command in Apartment Building mode
Command even with automation system secured or com-
mands activated
Partial opening (opening of leaf M2 to half of its total travel)
Partial opening (opening of both leaves to half of their total
travel)
Causes an opening manoeuvre at the end of which the
automation system is secured; the control unit does not
accept any other command except for the “Step-Step
high priority”, “Release” automation system or (only from
Oview) the commands: “Release and close” and “Release
and open”
Causes a closing manoeuvre at the end of which the
automation system is secured; the control unit does not
accept any other command except for the “Step-Step
high priority”, “Release” automation system or (only from
Oview) the commands: “Release and close” and “Release
and open”
Causes the manoeuvre to be stopped and the automation
system to be secured; the control unit does not accept
any other command except for the “Step-Step high priori-
ty”, “Release2 automation system or (only from Oview) the
commands: “Release and close” and “Release and open”.
Causes the automation system to be released and normal
operation to be restored
The Courtesy light output is turned on with timed switch-
off
The Courtesy light output is turned on and off in On-Off
mode
PRODUCT MAINTENANCE
9
In order to keep the safety level constant and to guarantee the maximum life
span of the entire automation system, regular maintenance is vital.
All maintenance work must be carried out in compliance with the safety provi-
sions of this manual and in accordance with existing laws and regulations.
The product requires frequent inspection to check for imbalances or signs of
wear or damage to the cables and springs. Do not use the product if adjust-
ments or repairs are required.
Important – During the product maintenance or cleaning operations, cut
off the electricity supply to the control unit.
For the other devices in the system, follow the instructions provided in their
respective maintenance schedules.
For gearmotors WL1024C, WL1024 and WL2024, scheduled maintenance is
required at the latest 6 months or 20,000 manoeuvres after the previous main-
tenance work.
Maintenance can be performed as follows:
01. Cut off any electrical power source, including any back-up batteries;
02. Check the condition and wear of all the materials making up the gearmotor,
paying special attention to erosion or rusting; replace all parts which do not
provide sufficient guarantees;
03. Reconnect the electrical power sources and perform all the checks envis-
aged in chapter 5.1 - Testing.
TABLE 12
SMXI / SMXIS or OXI / OXIFM / OXIT / OXITFM in mode I or Mode II
Output 1
Output 2
Output 3
Output 4
Command “P.P.” (Step-Step)
Command “partial opening 1”
Command “Opens”
Command “Closes”