Water Right Sanitizer Plus Series Installation Instructions & Owner's Manual

Manual is about: water conditioners

Summary of Sanitizer Plus Series

  • Page 1

    Sanitizer plus series ® water conditioners.

  • Page 2: Table of Contents

    Table of contents preinstallation instructions for dealers . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 bypass valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 3: Bypass Valve:

    Preinstallation instructions for dealers: bypass valve: 3 the manufacturer has preset the water treatment unit’s sequence of cycles, cycle times, salt dose, exchange capacity and salt dose refill time. The dealer should read this page and guide the installer regarding hardness, day override, and tim...

  • Page 4

    4 1. Normal operation position: the inlet and outlet handles point in the direction of flow indicated by the engraved arrows on the control valve. Water flows through the control valve for normal operation of a water softener. During the regeneration cycle this position provides regeneration water t...

  • Page 5: Installation:

    5 general installation & service warnings the control valve, fittings and/or bypass are designed to accommodate minor plumbing misalignments. There is a small amount of “give” to properly connect the piping, but the water softener is not designed to support the weight of the plumbing. Do not use vas...

  • Page 6

    6 6. Inlet/outlet plumbing: be sure to install bypass valve onto main control valve before beginning plumbing. Make provisions to bypass outside hydrant and cold hard water lines at this time. Install an inlet shutoff valve and plumb to the unit’s bypass valve inlet located at the right rear as you ...

  • Page 7: Programming Procedures:

    7 time hour set 2:00 am 1. Set time of day: 1 2 time minutes set 3 current day set mon 4 programming procedures: note: the manufacturer has preset the unit so that the gallons between regenerations will be automatically calculated after the hardness is entered. Step 1 – press next and + simultaneous...

  • Page 8

    Step 4 – regeneration hour: the manufacturer has factory set 2:00 a.M. As the default. This is the hour of day for regeneration and can be reset by using + or — buttons. “am/pm” toggles after 12. The default time is 2:00 a.M. (recommended for a normal household). Press next to go to step 5. Press re...

  • Page 9

    3 4 9 if the system has called for a regeneration that will occur at the preset time of regeneration, the words “regen today” will appear on the display. If a water meter is installed, “gpm” flashes on the display when water is being treated, indicating gallons per minute going through the system. 2...

  • Page 10

    10 4. Power loss and battery replacement: the ac transformer comes with a 15 foot power cord and is designed for use with the control valve; the transformer should only be used in a dry location. In the event of a power outage, the control valve will remember all settings and time of day. If an exte...

  • Page 11: Start-Up Instructions:

    11 • after installation is complete, rotate bypass handles to bypass mode (see fig.2 on page 4). • turn on water and check for leaks. • fully open a cold water faucet — preferably a laundry sink or bathtub without an aerator. • allow water to run until clear to rid pipes of debris which may have occ...

  • Page 12: Troubleshooting Guide:

    12 timer does not display time of day a. Transformer unplugged a. Reconnect transformer b. No power at outlet b. Repair or use working outlet c. Defective transformer c. Replace transformer d. Defective pc board d. Replace pc board timer does not display correct time of day or time of day flashes a....

  • Page 13

    Valve stalled in regeneration a. Motor not operating a. Replace motors b. No power at outlet b. Repair outlet or use working outlet c. Defective transformer c. Replace transformer d. Defective pc board d. Replace pc board e. Broken drive gear or drive cap assembly e. Replace gear or drive cap assemb...

  • Page 14: Replacement Parts:

    14 replacement parts: 2 7 1 3 5 4 6 front cover and drive assembly item no. Part no. Description qty. 1 cv3540s-a black cover 1 cv3540-ws-a gray cover 1 2 cv3107-1 motor 1 3 cv3106-1 drive bracket & spring clip 1 4 cv3554ws pc board, cc 1 5 cv3110 drive gear, 12 x 36 3 6 cv3109 drive gear cover 1 7 ...

  • Page 15: Replacement Parts:

    15 6 8 10 11 7 9 7 12 4 2 3 5 1 13 14 note: not available on 1¼ " valve. Replacement parts: piston assembly item no. Part no. Description qty. 1 cv3005 1" spacer stack assembly 1 cv3430 1.25" spacer stack assembly 1 2 cv3004 drive cap assembly 1 3 cv3135 o-ring 228 1 4 cv3011 1" piston assembly down...

  • Page 16: Replacement Parts:

    16 replacement parts: bypass valve item no. Part no. Description qty. 1 cv3151 nut, 1" quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3145 bypass rotor, 1" 2 5 cv3146 bypass cap 2 6 cv3147 bypass handle 2 7 cv3148 bypass rotor seal retainer 2 8 cv3152 o-ring 135 2 9 cv3155 o-ring 11...

  • Page 17: Replacement Parts:

    17 injector assemblies item no. Part no. Description qty. 1 cv3176 injector cap 1 2 cv3152 o-ring 135 1 3 cv3177 injector screen 1 4 cv3010-1z injector assembly plug 1 5 cv3010-1a a injector assembly, black 1 cv3010-1b b injector assembly, brown cv3010-1c c injector assembly, violet cv3010-1d d inje...

  • Page 18: Replacement Parts:

    Drain line assembly 3/4" item no. Part no. Description qty. 1 ch4615 elbow locking clip 1 2 cpkp10ts8-bulk optional insert, 5/8" tube 1 3 cv3192 optional nut, 3/4" drain elbow 1 4 cv3158-01 drain elbow, 3/4" npt with o-ring 1 5 cv3163 o-ring 019 1 6 cv3159-01 dlfc retainer assembly 1 7 cv3162-007 0....

  • Page 19: Replacement Parts:

    19 water meter & meter plug item no. Part no. Description qty. 1 cv3151 nut, 1" qc 1 2 cv3003 meter assembly, includes items 3 & 4 1 3 cv3118-01 turbine assembly 1 4 cv3105 o-ring 215 1 5 cv3003-01 meter plug assembly 1 6 cv3013 optional mixing valve 1 replacement parts:.

  • Page 20: Replacement Parts:

    20 replacement parts: 2 3 4 5 6 7 8 10 1 9 11 brine tank assembly item no. Part no. Description qty. 1 cg2191-49 brine tank cover, injection molded wr 1 cg2180 brine tank cover, standard 1 2 ch1072-01 optional 18" diameter salt grid 1 ch1080 optional 24" diameter salt grid 1 3 cg21833cb1c00 18" x 33...

  • Page 21

    21 1" pvc male npt elbow item no. Part no. Description qty. Cv3007 1" pvc male npt elbow assembly 2 1 cv3151 nut, 1" quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3149 fitting 2 3/4" & 1" pvc solvent elbow item no. Part no. Description qty. Cv3007- 01 3/4" & 1" pvc solvent elbow as...

  • Page 22

    22 1-1/4" & 1-1/2" pvc solvent item no. Part no. Description qty. Cv3007- 07 1-1/4" & 1-1/2" pvc solvent assembly 2 1 cv3151 nut, 1" quick connect 2 2 cv3150 split ring 2 3 cv3105 o-ring 215 2 4 cv3352 fitting 2 1-1/4" & 1-1/2" brass sweat item no. Part no. Description qty. Cv3007- 09 1-1/4 & 1-1/2"...

  • Page 23: Specifications:

    23 specifications: 1 all sanitizer plus water conditioners are pre-factory set at medium salting. Note: influent waters must be at least 3 gpg hardness and 80 tds. A calcite or corsex unit may be needed for correct operation. 2 iron removal may vary depending on form of iron, ph and other local cond...

  • Page 24: Quick Reference Guide:

    1900 prospect court • appleton, wi 54914 phone: 920-739-9401 • fax: 920-739-9406 manual regeneration note: for softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regeneration. If you need to initiate a manual regeneration, either immediately, or the sam...