Water Right Sanitizer Plus Series Installation Instructions & Owner's Manual - page 10
10
4. POWER LOSS AND BATTERY REPLACEMENT:
The AC transformer comes with a 15 foot power cord and is
designed for use with the control valve; the transformer should
only be used in a dry location.
In the event of a power outage, the control valve will remember
all settings and time of day. If an extended power outage occurs,
the control valve will keep time of day until the battery is depleted.
When the battery becomes depleted, the only item that needs to
be reset is the time of day and will be indicated by the time of
day flashing. All other settings are permanently stored in the
nonvolatile memory.
If a power loss occurs and the time of day flashes, this indicates that
the battery is depleted. The time of day should be reset and the non-
rechargeable battery should be replaced. The battery is a 3 Volt
Lithium Coin Cell type 2032 and is readily available at most stores.
To access battery location, remove front cover (see diagram on
page 14 for battery location).
5. CHECK SALT INDICATOR AND AUDIBLE ALARM: This control valve is equipped with a Low Salt
Warning to alert homeowners that the system is operating in a low salt condition. This usually indicates
that the salt level in the brine tank is too low to operate properly. If “CHECK SALT” appears on the screen,
there will usually be an audible alarm that sounds also (if turned on), alerting you to these conditions.
To turn off alarm: If the audible alarm sounds due to a low salt condition, press any button on the
face of the control valve to turn off. If salt is not added to the brine tank before the next regeneration, the
CHECK SALT indicator will alarm again.
IMPORTANT: If you feel that the salt level is adequate (at least 1/3 full) in the brine tank, please contact
the dealer that installed your system for service.
6. ERROR MESSAGE: If the word “ERROR” and a number are
alternately flashing on the display record the number and contact
your dealer for help. This indicates that the control valve was not
able to function properly.
6. BRINE TANK MAINTENANCE AND SALT: Refill the brine tank
as necessary, making sure at least 1/3 of the brine tank is full at all
times. Without proper salt levels, the water softener may not
operate properly.
Because “typical” settings of this water softener include a dry salt storage feature (no water in brine tank
between regeneration), the manufacturer recommends the use of solar salt for best results. The brine tank
is manufactured for the use of solar, pellets or rock salt. Do not use block salt. If pellet or rock salt is
used, a cleaning of the brine tank every six months is recommended. If the dry salt storage feature is not
being utilized, block salt may be used.
CAUTION:
Do not use any resin cleaners, nor place any resin cleaners
into the brine tank. Furthermore, do not use any salt that
indicates it is an iron cleaning salt or that contains any
cleaning additives. This may be harmful to the water softener
and for human consumption. Consult dealer for proper
cleaning instructions.
ERROR
BATTERY REPLACEMENT