Water Right Sanitizer Plus Series Installation Instructions & Owner's Manual - Specifications:
23
SPECIFICATIONS:
1
All Sanitizer Plus water conditioners are pre-factory set at medium salting. Note: influent waters must be at least 3 GPG
hardness and 80 TDS. A calcite or corsex unit may be needed for correct operation.
2
Iron removal may vary depending on form of iron, pH and other local conditions. On waters that are pre-chlorinated or
where other pre-oxidation occurs, an iron precipitate can form that is too small to be filtered.
3
The pH listed is the minimum for the influent water.
4
This is the minimum number of gallons at the continuous flow rate corrected to a 7 pH.The actual amount of pH adjusted
water may be greater.
5
Unit not tested for capacity at these flow rates. Water quality may vary.
MODEL
ASP1-1044
ASP1-1054
ASP1-1354
ASP2-1044
ASP2-1054
ASP2-1354
1
Capacity:
Maximum
11,800 @ 12.4
22,600 @ 15.9
36,900 @ 21.2
20,300 @ 12.4
34,800@ 15.9
60,300 @ 26.5
(Grains/Lbs. NaCI)
Medium
11,400 @ 9.3
20,700 @ 12.4
33,600 @ 15.9
19,100 @ 9.3
32,000 @ 12.4
48,300 @ 15.9
Minimum
7,300 @ 3.2
16,400 @ 6.1
28,300 @ 9.5
11,100 @ 3.2
22,900 @ 6.1
28,200 @ 9.3
Amount of Media (Cu. Ft.)
1.0
1.5
2.5
1.0
1.5
2.5
Maximum Water Hardness (GPG)
20
30
40
40
60
80
2
Maximum Iron (PPM)
8.0
10.0
15.0
8.0
10.0
15.0
3
Minimum pH Required
6.5
6.0
6.0
7.0
7.0
7.0
4
Total pH Adjusted Water at Continuous Flows
630
252
432
NA
NA
NA
5
Peak Flow Rate (GPM @ P-PSI)
19 @ 15.0
17 @ 15.0
19 @ 15.0
19 @ 15.0
17 @ 15.0
19 @ 15.0
Continuous Flow Rate (GPM @ P-PSI)
9.0 @ 5.0
8.0 @ 5.0
9.0 @ 5.0
9.0 @ 5.0
8.0 @ 5.0
9.0 @ 5.0
Water Pressure Range (PSI)
25-100
25-100
25-100
25-100
25-100
25-100
Water Temp. (ºF)
33-100
33-100
33-100
33-100
33-100
33-100
Electrical Requirements (volts-hertz)
110-50/60
110-50/60
110-50/60
110-50/60
110-50/60
110-50/60
Pipe Size
1"
1"
1"
1"
1"
1"
Total Dimensions:
Media Tank
10"W x 52"H
10"W x 62"H
13"W x 62"H
10"W x 52"H
10"W x 62"H
13"W x 62"H
Brine Tank
18"W x 33"H
18"W x 33"H
18"W x 40"H
18"W x 33"H
18"W x 33"H
18"W x 40"H
MODEL
ASPR-1044
ASPR-1054
ASPR-1354
ASPR-844
1
Capacity:
Maximum
32,000 @ 15.0
48,800 @ 21.0
72,800 @ 24.0
25,600 @ 9.0
(Grains/Lbs. NaCI)
Medium
28,400 @ 9.0
44,400 @ 15.0
64,200 @ 18.0
21,600 @ 6.0
Minimum
23,600 @ 6.0
35,400 @ 9.0
53,000 @ 12.0
15,600 @ 3.0
Amount of Media (Cu. Ft.)
1.0
1.5
2.5
0.85
Maximum Water Hardness (GPG)
75
100
100
50
2
Maximum Iron (PPM)
1.0
1.0
1.0
1.0
3
Minimum pH Required
7.0
7.0
7.0
7.0
4
Total pH Adjusted Water at Continuous Flows
NA
NA
NA
NA
5
Peak Flow Rate (GPM @ P-PSI)
17.1 @ 15.0
14.3 @ 15.0
18.5 @ 15.0
11.4 @ 15.0
Continuous Flow Rate (GPM @ P-PSI)
5.0 @ 2.8
5.0 @ 3.8
5.0 @ 2.4
5.0 @ 5.4
Water Pressure Range (PSI)
25-100
25-100
25-100
25-100
Water Temp. (ºF)
33-100
33-100
33-100
33-100
Electrical Requirements (volts-hertz)
110-50/60
110-50/60
110-50/60
110-50/60
Pipe Size
1"
1"
1"
1"
Total Dimensions:
Media Tank
10"W x 52"H
10"W x 62"H
13"W x 62"H
8"W x 52"H
Brine Tank
18"W x 33"H
18"W x 33"H
18"W x 40"H
18"W x 33"H
MODEL
ASP1-1044
ASP1-1054
ASP1-1354
ASP2-1044
ASP2-1054
ASP2-1354
ASPR-1044
ASPR-1054
ASPR-1354
ASPR-844
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
MIN.
GAL.
Brine Refill
5:51
3
9:53
5
11:53
6
5:51
3
9:53
5
11:53
6
5:51
3
9:53
5
11:53
6
3:51
2
Backwash
12
42
12
48
12
84
12
36
12
42
12
60
8
22
8
22
10
32
6
10
Brine & Rinse
72
29
90
36
90
72
72
29
90
36
90
72
60
24
90
36
90
47
40
16
Rapid Rinse
4
14
4
16
4
28
4
12
4
14
4
20
4
11
4
11
4
13
4
7
Total
94
88
116
105
118
190
94
80
116
97
118
158
78
60
112
74
116
98
54
35