Special Functions (cont):
Check signal strength:
To check the signal strength (0-31), you would send the following SMS command to the unit.
*CSQ?#
Example of Returned Message:
CSQ=<27>
Power Loss Report:
The unit is able to send alert message to the administrator in the event the main power is out / turned off. When the main power is
restored it can notify the administrator again the main power is on.
When main power OFF
The unit will send a message: ACP-OFF
Note: At the same time, it will send an ALWAYS high pulse out from I/O port. Alarm will sound.
When main power restored
The unit will send a message: ACP-O9
Intercom Volume:
It is possible to adjust the volume (from level 1 to 6) of the intercom by sending the following SMS command. Factory Default:
4
Example: Sending the following SMS Command
*SOUD#5 – Adjust the volume to 5
Example of Returned Message:
SOU9D:<5>
Remote System Check:
It is possible to check the system is operating correctly by sending the following SMS command to the unit.
Send the following SMS Command:
*TEST#
When the unit replies TEST-OK indicate the unit is operating correctly.
9ote: If you receive no reply then unit is not working