Webasto Air Top Evo 40 Installation Instructions Manual - 12 Technical Data
23
Air Top Evo 40 | Air Top Evo 55
12 Technical data
12.1 Heater
Heater
Air Top Evo 40 B
Air Top Evo 40 D
Air Top Evo 55 B
Air Top Evo 55 D
Type approval: EMC
E1 03 5529
Type approval: Heating
E1 00 0385
E1 00 0386
Design
Air heater with vaporising burner
Heat flow over control range [kW]
1.7 to 3.5 (4.0)
1.5 to 3.5 (4.0)
1.7 to 5.0 (5.5)
1.5 to 5.0 (5.5)
Fuel
Petrol DIN EN 228
Diesel / biodiesel DIN EN 590/
DIN EN 14214
Petrol DIN EN 228
Diesel / biodiesel DIN EN 590/
DIN EN 14214
Fuel consumption over control range
0.18 to 0.38 (0.43) kg/h
0.25 to 0.51 (0.58) l/h
0.15 to 0.36 (0.41) kg/h
0.18 to 0.43 (0.49) l/h
0.18 to 0.54 (0.59) kg/h
0.25 to 0.73 (0.80) l/h
0.15 to 0.51 (0.56) kg/h
0.18 to 0.61 (0.67) l/h
Rated voltage [V]
12
12 / 24
12
12 / 24
Operating voltage range [V]
10.5 to 16
10.5 to 16 / 20.5 to 31
10.5 to 16
10.5 to 16 / 20.5 to 31
Rated power consumption over control range [W]
15 to 40 (55)
15 to 95 (130)
Permissible ambient temperature (operation/storage):
Heater [°C]
–40 to +40 / –40 to +85
Permissible ambient temperature (operation/storage):
Fuel pump [°C]
–40 to +20 / –40 to +85
Permissible combustion air intake temperature [°C]
–40 to +20
Setpoint temperature range [°C]
+5 to +35
Volumetric flow rate with pressure loss in cold/hot air sys-
tem 0.5 hPa [m
3
/h]
max. 132 (140)
max. 200 (220)
CO
2
in exhaust gas: Rated heating capacity VL [kW]
3.5
5.0
CO
2
in exhaust gas: CO
2
rated value VL [vol%]
8.9
9.2
10.0
Heater length [mm]
423 ± 2
Heater width [mm]
148 ± 1
Heater height [mm]
162 ± 1
Heater weight [kg]
5.9
IP class: Heater
IP5K4K
IP class: Fuel pump
IPX6 / IPX7 / IP6K9K
Max. length of combustion air line and exhaust line
with exhaust silencer [m]
2
Max. length of combustion air line and exhaust line
without exhaust silencer [m]
5
Max. permissible pressure loss in cold and hot air system
[hPa]
2.0
3.0
The technical data apply under following conditions:
■
Ambient temperature: +20 °C
■
Geodetic height: 0 m above sea level
■
Rated voltage
The standard tolerances of ±10 % for heaters shall apply if no limits are specified.
The values in brackets apply for the extended heating capacity (boost function) that is activated temporarily during each
start.