Weber 3600 Installation Manual - page 8
8
WWW.WEBER.COM
®
CLEARANCES FROM COMBUSTIBLE MATERIALS
2
2
2
1
1
Q
®
3600
™
cookbox
2
457 mm (18") from edge of cookbox to any combustible surface
REQUIRED CLEARANCES FROM
COMBUSTIBLE MATERIALS
Clearance dimensions indicate the minimum allowable
distance from the edge of the cookbox to any combustible
materials.
m WARNING: The structure, countertops,
and adjacent work areas for the
built-in barbecue installation must
be constructed from noncombustible
materials only.
NOTE: If you have questions on which materials are
considered noncombustible, contact your local building
materials supplier or fire department.
REQUIRED CLEARANCES FROM
NONCOMBUSTIBLE MATERIALS
If your installation is to be adjacent to noncombustible
materials, you must consider these dimensions for
minimum lid clearances.
m WARNING: The structure, countertops,
and adjacent work areas for the
built-in barbecue installation must
be constructed from noncombustible
materials only.
NOTE: If you have questions on which materials are
considered noncombustible, contact your local building
materials supplier or fire department.
PLANNING AHEAD
LID CLEARANCES - INSTALLATION ADJACENT TO A NONCOMBUSTIBLE WALL
a
1
2
4
3
DIMENSIONS
DESCRIPTION
1
25 mm (1")
Minimum behind for lid clearance
2
89 mm (3
1
⁄
2
")
Minimum from edge of cutout to wall
3
76 mm (3")
Minimum above for lid clearance
4
635 mm (25
3
⁄
4
")
Minimum countertop to lid clearance height
a
Wall made from noncombustible materials