Weda WP300 Instructions & Spare Parts Catalogue

Manual is about: Submersible Water Pump

Summary of WP300

  • Page 1

    Weda pump submersible water pump wp300 instructions & spare parts catalogue wp300_ eng_1.

  • Page 2

    2 safety instructions .............................................................................. 3,4 technical data .................................................................................... 5 pre-operation note..............................................................................

  • Page 3: Safety Instructions

    3 safety instructions - machines submitted : powered with : electric, pneumatic, petrol or diesel engine. - symbols : the words warning and caution used in safety instructions, have the following meanings : warning indicates hazards or hazardous procedures which could result in serious injury or dea...

  • Page 4

    4 - power supply : warning make sure that the power supply equipment complies with the relevant safety requirements of the local and the international standards. - electric machine : it must be ensured that the machine is connected to the voltage and the frequency specified on the name plate. The po...

  • Page 5: Technical Data

    5 technical data type of current 1-phase – 50 hz voltage 230v power 650w rated current 3.5a maximum capacity (q. Max) 250 liter/min (15m 3 /h) max. Water temp 35 o particle max. 5 mm max. Height of water (h. Max) 11m weight (without cable) 13.3kg height 38cm diameter 18cm ce- approved.

  • Page 6: Pre-Operation Notes

    6 pre-operation notes the warranty will be void if the pump has not been operated and maintained in the manner prescribed in this operator's manual. In order for the pump to perform at its optimum capabilities, the operator of the unit must read this manual thoroughly before using this unit. This op...

  • Page 7: Safety Precautions

    7 safety precautions 1. Read and understand operator's manual prior to use of submersible pump. 2. Do not use electrical cable to carry, lift or otherwise move pump. This will damage the cable, which can cause electrical shocks, electrical short circuit, pump failure, personal injury and other accid...

  • Page 8

    8 9. Do not continue operating the pump if any of the following conditions are observed: a. Excessive vibration b. Unusual odor or noise turn pump off immediately if any of the above conditions appear and contact your local dealer. 10. Check hoses for weak or worn condition before each use, and maki...

  • Page 9: Setting Up The Wp300

    9 setting up the wp300 1. Wrap threaded sections of included nipple with teflon tape. 2. Screw prepared nipple onto the wp300 submersible pump. Do not overtighten coupling onto the outlet as this may lead to damaging the pumps structural integrity. 3. Connect 2" discharge hose to pump. Do not use re...

  • Page 10: Pre-Operating Procedures

    10 pre-operating procedures before attempting to operate the wp300 submersible pump, please perform the following procedures for the personal and property safety of the operator and jobsite. 1. Ensure that the pump is structurally and mechanically safe by checking the following: a. Does the pump sta...

  • Page 11: Never Run Pump Dry.

    11 2. Before using the pump on proposed jobsite, perform the following environmental checks: a. Check that available electrical socket conforms to local codes. B. Inspect the entire work area for unexpected buried hazards, such as rocks, pins, nails and other obstructions that can be sucked into the...

  • Page 12: Operation

    12 operation procedures 1. Place the pump assembly (pump & discharge hose) in an upright position. Always ensure that the pump will be operating in an upright position 2. Slowly lower pump into jobsite, using a rope, chain, or other implements attached to the handle. Never use electrical cable to ca...

  • Page 13: Removed.

    13 3. Plug grounded electrical plug into a grounded socket: make sure that cable, plug and socket are all dry and clean. Do not mix. Water and electricity do not use pump if electrical cable shows any of the following signs: 1. Electrical cable is frayed or shows signs of wear, such as ripped cord c...

  • Page 14: Maintenance Procedures

    14 maintenance procedures regular scheduled maintenance procedures will help to maintain your pump's life and performance. Before performing any maintenance, disconnect the pump from power source. Make sure that cable, plug and socket are all dry and clean. Do not mix water and electricity. Standard...

  • Page 15: Winterizing Your Pump

    15 winterizing your pump the wp300 submersible pump cannot freeze as long as it remains submerged and in operation at the pump site in which it was originally installed. The discharge hose must be free from any obstructions or damages that can cause the improper discharge of water. If the pump is re...

  • Page 16: Maintenance Schedule

    16 maintenance schedule frequency maintenance actions after every use: a. Clean the pump surface of any accumulated dirt with water b. Remove base, filter and pump cover to check and remove any debris from impeller. C. Re-attach and secure pump cover, filter and base. D. Make sure pump has been wash...

  • Page 17: Troubleshooting Guide

    17 troubleshooting guide issue cause solution 1. Pump does not start 1. Wrong voltage check that pump is plugged into a socket with the proper voltage. 2. No power check that pump is plugged into a live socket. 3. Damaged electrical cable do not use pump. Contact your dealer for further instructions...

  • Page 18: Troubleshooting Guide

    18 troubleshooting guide 2. Water is in the stator housing 1. Damaged seals complete pump overhaul. 2. Damaged cable entrance do not use pump. Contact your dealer for further instructions. 4. Water in the oil housing 1. Worn or damaged oil lipseals and/or mechanical seals change seals. See “ mainten...

  • Page 19

    19 spare parts catalogue ordering spare parts to avoid errors in delivery, please give the following information when ordering spare parts : 1. Type of machine. 2. Machine serial number. 3. Quantity required. 4. Part number. 5. Parts description. 6. Dimensions when ordering per length..

  • Page 20

    21 ref description p/n qty 1 top cover psp200ss-1 1 2 capacitor psp200ss-2 1 3 top o-ring psp200ss-3 1 4 motor cover not available 1 5 bearing not available 1 6 rotor not available 1 7 bearing not available 1 8 motor stator not available 1 9 bottom o-ring psp200ss-9 1 10 motor base not available 1 1...

  • Page 21

    22.

  • Page 22

    23 2007-11-20