Weda WP300 Instructions & Spare Parts Catalogue - Removed.
13
3. Plug grounded electrical plug into a grounded socket:
MAKE SURE THAT CABLE, PLUG AND
SOCKET ARE ALL DRY AND CLEAN.
DO NOT MIX. WATER AND ELECTRICITY
DO NOT USE PUMP IF ELECTRICAL CABLE
SHOWS ANY OF THE FOLLOWING SIGNS:
1. Electrical cable is frayed or shows signs of wear, such
as ripped cord casing, acute bends in cord, etc, or if
electrical plug is not securely connected to the cable.
This can result in electrical shock or leakage.
2. Electrical cable is looped or placed on a gas pipe, water
pipe, lightning arrestor, telephone wire or any other utility
lines.
3. Electrical cable is overextendedvby attempting to lower
pump farther than the length of the factory supplied
cable or 8 m (26' feet), whichever is shorter.
4. Electrical wire is cut, twisted or damaged in any way.
This may result in electrical shock and leakage which
can cause injury to the operator, jobsite and/or the pump.
DO NOT use pump if there are no grounded electrical
sockets on jobsite OR if the ground connection on
electrical plug has been damaged in any way or
removed.
DO NOT use pump if strain relief is not securely
attached.
4. When operating pump, ensure that stops and starts of pump
do not exceed 6 times per hour.
Do not attempt to run the pump dry, as permanent damage to
the mechanical seal will result.