MAINTENANCE SCHEDULE
FREQUENCY MAINTENANCE
ACTIONS
After every use:
a. Clean the pump surface of any
accumulated dirt with water
b. Remove base, filter and pump cover to
check and remove any debris from impeller.
c. Re-attach and secure pump cover, filter and
base.
d. Make sure pump has been washed and
dried before storing pump away.
After every week:
a. If pump is part of a permanent installation,
make sure that the pump is run at least
once a week to prevent it from locking up.
After first 15 hours of operation:
a. Check oil in pump. See “Maintenance
Procedures” for instructions.
b. Visually check pump housing and impeller
for wear and tear. Change parts if
performance of pump has been impaired.
After every 100 hours of
operation:
a. Check oil in pump. See “Maintenance
Procedurs” for instructions.
b. Visually check pump housing and impeller
for wear and tear. Change parts if
performance of pump has been impaired.
After every 1000 hours of
operation or every 6 month,
whichever comes first.
a. Change oil in pump. See “Maintenance
Procedures” for instructions.
b. Change mechanical seals. See “
Maintenance Procedures” for instructions.
c. Visually check pump housing and impeller
for wear and tear. Change parts if any signs
of excessive wear can be detected or if