WEG DeviceNet CFW500 User Manual - page 20

Manual is about: Variable Frequency Drives

Summary of DeviceNet CFW500

  • Page 1

    Profibus dp cfw500 user’s manual phone: 800.894.0412 - fax: 888.723.4773 - web: www.Ctiautomation.Net - email: info@ctiautomation.Net.

  • Page 2

    Profibus dp user’s manual series: cfw500 language: english document number: 10002253408 / 00 publication date: 06/2013 phone: 800.894.0412 - fax: 888.723.4773 - web: www.Ctiautomation.Net - email: info@ctiautomation.Net.

  • Page 3

    Contents contents ............................................................................................................................... 3 about this manual............................................................................................................ 5 abbreviations and defini...

  • Page 4

    P0743 – profibus reading #4 ............................................................................................... 18 p0744 – profibus reading #5 ............................................................................................... 18 p0745 – profibus reading #6 .....................

  • Page 5

    About this manual this manual provides the necessary information for the operation of the cfw500 frequency inverter using the profibus dp interface. This manual must be used together with the cfw500 user’s guide. Abbreviations and definitions dp decentralized periphery eia electronic industries alli...

  • Page 6

    1 introduction to the profibus dp protocol a general overview of profibus dp protocol, describing the main characteristics and functions, are presented next. 1.1 profibus dp network the term profibus is used to describe a digital communication system that can be used in several application areas. It...

  • Page 7

    The profibus dp accessory of the cfw500 frequency inverter provides an rs485 interface for network connection. 1.5 application profile – profidrive complementary to the profibus protocol specification, the profidrive specification, elaborated and kept by the profibus international, basically describ...

  • Page 8

    2 profibus dp communication accessory the following profibus dp accessory is needed in order to enable the device communication in a profibus dp network. Information about the installation of this module can be found in the guide that came with the accessory. 2.1 plug-in module cfw500-cpro weg part ...

  • Page 9

    3 installation in the profibus dp network the profibus dp network, such as several industrial communication networks, for being many times applied in aggressive environments with high exposure to electromagnetic interference, requires that certain precautions be taken in order to guarantee a low com...

  • Page 10

    Connected to the network. Each repeater must also be included as a device connected to the segment, even not occupying a network address. It is recommended that the connection of all the devices present in the profibus dp network be made coming from the main bus. Generally, the profibus network conn...

  • Page 11

    4 programming next, the cfw500 frequency inverter parameters related to the profibus dp communication will be presented. 4.1 symbols for the properties description ro read-only parameter cfg parameter that can be changed only with a stopped motor dp parameter visible on the hmi if the product has th...

  • Page 12

    Table 4.1: p0313 options options description 0 = inactive no action is taken and the drive remains in the existing status. 1 = disable via run/stop a stop command with deceleration ramp is executed and the motor stops according to the programmed deceleration ramp. 2 = disable via general enable the ...

  • Page 13

    Table 4.2: p0680 parameter bit functions bits values bits 0 to 3 reserved. Bit 4 active quick stop 0: the fast stop command is not active. 1: the drive is executing the fast stop command. Bit 5 second ramp 0: the drive is configured to use the first ramp values, programmed in p0100 and p0101, as the...

  • Page 14

    Note! The values transmitted over the network have a scale limitation, allowing a maximum of 4 times the synchronous speed of the motor, with saturation in 32767 (or -32768). P0684 – profibus dp control word range: 0000h to ffffh default: 0000h properties: - access groups via hmi: net description: i...

  • Page 15

    In order that the reference written in this parameter be used, it is necessary that the drive be programmed to use the speed reference via canopen/devicenet/profibus dp. This programming is achieved by means of parameters p0221 and p0222. This word uses a 13-bit resolution with signal to represent t...

  • Page 16

    Table 4.4: p0695 parameter bit functions bits values bit 0 do1 setting 0: do1 output open. 1: do1 output closed. Bit 1 do2 setting 0: do2 output open. 1: do2 output closed. Bit 2 do3 setting 0: do3 output open. 1: do3 output closed. Bit 3 do4 setting 0: do4 output open. 1: do4 output closed. Bit 4 d...

  • Page 17

    P0740 – profibus dp communication status range: 0 = inactive default: - 1 = profibus interface initialization error 2 = offline 3 = configuration data error 4 = parameterization data error 5 = clear mode 6 = online properties: ro access groups via hmi: net description: it allows identifying if the p...

  • Page 18

    Speed for profidrive profile: if the used profile is the profidrive, both the speed reference and the motor speed must be indicated as a value proportional to the drive maximum speed, programmed through p0134: value via profibus = 0000h (0 decimal) → speed = 0 hz value via profibus = 4000h (16384 de...

  • Page 19

    Note! The value 0 (zero) disables the reading in the word. The number of input words, however, keeps the same as programmed at p0922. P0750 – profibus writing #3 p0751 – profibus writing #4 p0752 – profibus writing #5 p0753 – profibus writing #6 p0754 – profibus writing #7 p0755 – profibus writing #...

  • Page 20

    P0922 – selection of the configuration telegram range: 2 = standard telegram 1 (2 i/o words) default: 2 valores: 3 = telegram 103 (3 i/o words) 4 = telegram 104 (4 i/o words) 5 = telegram 105 (5 i/o words) 6 = telegram 106 (6 i/o words) 7 = telegram 107 (7 i/o words) 8 = telegram 108 (8 i/o words) p...

  • Page 21

    P0967 – profidrive control word range: 0000h to ffffh default: 0000h properties: dp access groups via hmi: net description: it is a profibus dp communication specific parameter, defined by the profidrive standard, with the inverter control word via the profibus dp interface when the profidrive data ...

  • Page 22

    P0968 – profidrive status word range: 0000h to ffffh default: - properties: ro, dp access groups via hmi: net description: it is a profibus dp communication specific parameter, defined by the profidrive standard, with the drive status word via the profibus dp interface when the profidrive data profi...

  • Page 23

    5 profibus dp network operation the cfw500 frequency inverter with profibus dp communication accessory operates as a slave in the network and supports the network services of dp-v0 and dp-v1 communication protocols. Information about the inverter operation using the services specified on these versi...

  • Page 24

    Communication between class 2 master and slave (ms2): initiates the connection (initiate) data acyclic reading (ds_read) data acyclic writing (ds_write) aborts the connection (abort) dp-v1 requests use an sd2 type profibus dp telegram – with variable data length. This type of telegram has the follow...

  • Page 25

    Positive response (slave -> master) header data unit (du) end function 5fh slot 0 index 47 size 0 negative response (slave -> master) header data unit (du) end function dfh error decode 128 error code 1 xx error code 2 xx reading telegram (ds_read): request (master -> slave) header data unit (du) en...

  • Page 26

    2. When receiving the telegram, the cfw500 will test the data consistency in order to know if the request is valid. If errors in the request format are not found, it will respond positively to the request telegram and initiate the data treatment. 3. After receiving writing telegram positive response...

  • Page 27

    Request reference mirror a mirror of the value received in the request telegram. Response id it represents the type of response sent by the slave: 1 = successful parameter reading 2 = successful parameter modification 129 = parameter reading with error 130 = parameter modification with error do-id m...

  • Page 28

    6 faults and alarms related to the profibus dp communication a138/f238 – profibus dp interface in clear mode description: it indicates that the slave has received from the network master the command to enter the clear mode. Actuation: the indication occurs if, during the cyclic communication, the pr...

  • Page 29

    The message of alarm a140 or fault f240 will in this case be signalized through the hmi, depending on the p0313 programming. It is necessary to cycle the power of the drive so that a new attempt to access the profibus dp module is done. Possible causes/correction: verify whether the profibus dp modu...