Xpresskit XK09 Installation Manual - page 6
User Configuration - Optional Programming
1
Insert the key into the ignition at the OFF position and hold
the Programming button down for at least 2 seconds.
The LED flashes rapidly for 2 seconds to confirm you are
in programming mode.
&
Flash 2 Secs
&
ON
START
OFF
KEY
Press & Hold
Key at OFF
6
Remove the key from the ignition barrel.
O
N
START
OFF
KEY
Remove Key
5
To exit the programming mode, hold the Programming button down until
the LED flashes once quickly.
Flashes Once
&
Press & Hold
3
To change the MODE, press once on the Programming button. The LED
confirms the MODE with a number of slow flashes.
Only modes 6, 7 and 8 are available.
&
Press Once
No. of Slow
Flashes = Mode
2
Release the Programming button. The LED first flashes
a number of times slowly to indicate the MODE. It then
flashes a number of times quickly to indicate the OPTION.
&
No. of Slow
Flashes = Mode
No. of Quick
Flashes = Option
&
Release
4
To change the OPTION in the selected MODE, press LOCK or
UNLOCK on the alarm or remote starter transmitter. The LED confirms
the OPTION with a number of quick flashes.
See the list of options at the bottom of this page.
&
No. of Quick
Flashes = Option
or
(
(
Press
USER MODES are identified by a slow LED flashing pattern. For example, 1 slow flash = Mode1 and 2 slow
flashes = Mode 2.
Page 6
Mode 6 - Lock when remote starter stops
Mode 7 - Alarm control
Mode 8 - Reset
*Option 1: Activate.
*Option 1: Vehicle with alarm.
*Option 1: No reset.
Option 2: Deactivate.
Option 2: Vehicle without alarm.
Option 2: Complete reset of the
options and module.
* Default option.
Rev.: 20100302
Platform: XK09
Firmware: DLCH3