If you press any test/learn button on any learnt-in
sensor (confirm by pressing 3), these sensors will be
excluded during the Home Arm mode.
Repeat this step to exclude additional sensors.
Devices
Select ‘Devices’ in the set-up programming menu to
add or remove a device. From here you will be able
to view a list of all the devices being installed and
you can add or delete devices. The following items
can be selected.
· Add Device
· Edit Devices
· Remove Device
· Program Siren
Add Devices
1. To learn-in a new device select ‘Add Device’ then
press 3, a “press learn button on device to add”
message will be shown.
2. Press the learn button on the device within 30
seconds (see Chapter 2 for location).
3. If a signal is detected, the screen will show the
type of device found.
• Devices are labeled by the following codes within
the Control Panel:
· Door/Window Contact
DC
· PIR Motion Detector
PIR
· Key Fob
RC
· External Siren
BX
· Key Pad
KP
• When a sensor is added to the system for
a second time, an error “Already in System”
message will be briefly displayed and the Control
Panel will wait for another learn-in signal.
4. Press 3 to confirm the device type.
5. The following zone types will need setting
for Door/Window Contacts and PIR Motion
Detectors:
· Burglar
· Home Omit
· Entry
· Away Entry
· 24 Hour (DC only)
The following devices have a fixed
emergency zone
type:
· Smoke Detector
· Key Fob (+Button)
· Panic Button
· Key Pad (2 red buttons)
Zone Type List
Burglar
• When the system is armed and a device is
triggered, the alarm will be activated immediately.
• A device set to burglar will not trigger an alarm
during entry or exit delay periods.
Home Omit
• A home omit device will be ignored when the
system is Home Armed.
• A home omit device will give a burglar alarm when
the system is Away Armed.
Entry
• If an entry device is triggered when the system
is either Away or Part Armed, it will start an entry
delay period to give enough time to disarm the
system.
• If the delay period expires without being disarmed,
the Control Panel will respond with a burglar alarm.
• If the device has been set to entry and triggered
when the system is in disarmed mode, the Control
Panel will make a ‘ding-dong’ door chime sound if
the door chime feature is enabled.
Away Entry
• If an Away Entry device is triggered when the
system is in Armed mode, the Control Panel will
start an entry delay period to give enough time to
disarm the system.
• If the delay period expires without being disarmed,
the Control Panel will respond with a burglar alarm.
• An Away Entry device is ignored when Home
Armed.
• The device will not give a “ding dong” chime sound
when door chime is selected.
24 Hour
• The door/Window Contact is the only device that
has this zone type, the PIR Motion Detector does
not.
17