Zanussi Electrolux Electric cooker User Manaul - page 14
29
ADAPTATION TO DIFFERENT TIPES OF GAS
REPLACING THE OVEN BURNER
INJECTOR
To adapt the appliance to a different gas type from the
one which the appliance has been set for, it is necessary
to replace the oven injector whith the proper one (see
table 1). To carry out this operation, open the oven door
and act as follows:
— remove the oven bottom “A” (Fig. 22), completely
discovering the oven burner “B”;
— undo the fixing screws “C” (Fig. 23) which hold the
ignition device in place;
— uno the fixing screw “D” which hold the oven burner
in place;
— gently remove the oven burner (Fig. 24);
— with a 7 mm. socket spanner remove the injector
and replace it with the proper one (see tab.1).
Replace the gas supply label positioned near the gas
supply ramp, with the proper one, provided with the
injectors kit.
Fig. 22
a
b
injectors
Normal Gas flow
Reduced
By-pass
Gas Feeding
diameter
power
in
power
1/100 mm
Pressure
Gas type
1/100 mm
kW
I/h
g/h
kW
Natural gas (G20)
114
2.7
257
-
1.1
Reg.
20
Butane (G30)
78
2.5
-
180
1.1
52
28-30
Propane (G31)
78
2.5
-
180
1.1
52
37
Table 1
The oven burner does not need any air regulation.
If gas pressure is different (or variable) from the proper
one, a suitable pressure regulator should be installed
on feeding pipe.
The use of pressure regulators for liquid gas (LPG) is
allowed provided they are modelled in conformity with
the rules in force.