Procedure:
1) Take the handset that has already been programmed to communicate with the front gate. Press
the red button 8 and blue button 9 at the same time to get into programming mode.
2) Take the back gate caller station and ensure that the dip switches 6 are set the same
channel as the handset. All units must be on the same channel.
3) Put the dip switch 3 in the caller unit to PAIRING (towards the right) and insert 4x AA (penlight)
batteries into the compartment. The LED light 2 on the caller unit should flash every second.
4) Press the CALL button 10 on the Handset and the handset should beep once to acknowledge
the pairing. Press the red button 8 once on the handset to get out of programming mode.
5) The LED 2 on the caller unit will flash slowly every 2 seconds indicating that the caller unit
is programmed.
6) Put the dip switch 7 in the caller unit to NORMAL and test the calling feature by pressing the
button 1 on the caller unit.
7) The handset should ring within 5 seconds and indicate station B.
CAUTION : Remember to set the yellow dip switch 7 back to NORMAL position after
pairing or cloning procedures, otherwise the caller unit will not operate properly.
Gate opening
•
AC or DC voltage of 8-12V is needed in order to open a lock. Battery power will only operate
the intercom function but not the door opening. The door station has been designed to open
an electric door lock (strike lock) as a 4 second pulse of low voltage AC power is sent to the lock.
A relay board (available from the supplier) is needed to trigger a gate motor.
•
Opening or closing of the gate can occur at any time. If a call is in progress press the lock button
11 (round) on the handset and the door opening icon will appear on the screen after 3 second.
To open/ close the gate at any time keep the lock button pushed until the door opening icon
appears.
•
Always insert AA batteries into the caller unit before connecting AC/DC power. The LED should
illuminate as soon as batteries are inserted and then switch off immediately afterwards. If the
light remains on, check that the dip switch 7 is not set to PAIRING.
Connection pins at the back of Caller unit
AC/DC Supply (pins 1 & 2)
Under no circumstances should AC mains Voltage be directly connected to the terminal.