3Com NETBuilder SI Using Manual - System
Other manuals for NETBuilder SI:
User Manual
Manual is about: Bridge/Router
of
212
Error LED Meanings
127
Meaning:
The software image file has been deleted or the boot source
and image names do not match.
Action:
Follow these steps:
1 At the monitor prompt, enter:
DF
The default path is:
DF /primary
The image is called boot.68k.
2 If the image has been deleted, reload the software using Appendix B.
3 If the image has a different name or is in a different directory, boot from
the image using:
BT [
Meaning:
File too large.
Action:
Check to see if the file is larger than available memory. Turn
the power off and then on again to retry the system software
SYSTEM
Status
Run
Test
Power
/Fault
Load
Aux
Fwd
Amber
Amber
SYSTEM
Status
Run
Test
Power
/Fault
Load
Aux
Fwd
Amber
Amber