C
HAPTER
6: B
ASIC
C
ONFIGURATION
OF
P
ORTS
AND
P
ATHS
before you connect it to the SuperStack II bridge/router. See the
documentation that came with your TA for more information.
To configure the serial port with a DCE, follow these steps:
1 The default baud rate for the serial port is 64 Kbps. If you need to change
the baud rate, use:
SETDefault !
2 The default device type is Modem. Specify the external device type
attached to the Flex-WAN cable using:
SETDefault !
3 If you have changed any of the default settings, re-enable the path to
make sure all settings on the path take effect using:
SETDefault !
Configuring Serial
Ports with DTEs
This section describes how to configure the serial ports when connecting
directly to IBM legacy equipment.
Before beginning this procedure, complete the following tasks:
■
Attach the Flex-WAN cable to the serial port and the DTE.
■
Log on to the system with Network Manager privilege.
The Flex-WAN serial port automatically detects the following settings:
■
Line type — leased
■
Clock — internal
■
Connector type — RS-232, V.35, X.21, or RS-449
To configure the serial port with a DTE, follow these steps:
1 The default baud rate for the serial port is 64 Kbps. If you need to change
the baud rate, use:
SETDefault !
2 Set the owner of the serial port using:
SETDefault !
See Using Enterprise OS Software for more information about IBM legacy
protocols.