3D Systems ProX DMP 300 User Manual - page 80
76
3D SYSTEMS, INC
.
PN:80-D27 Rev.B
PREVENTIVE MAINTENANCE SCHEDULE
Maintenance not listed on this section is only allowed to be performed by 3D Systems-certified Customer Support Engineer.
ITEM
SPECIFICATION
ONCE A
MONTH
EVERY 3
MONTHS
EVERY 6
MONTHS
EVERY YEAR
Air pressure
Check : 5 .5 bar
X
Pinch valve pressure
Check : 3 .5 X Gas pressure Check : 4 bar X Gas flow Check : 10 X Unclogging systems pressure Check : 2 bar X Sieve screen Clean X Carriage Lubricate X Gloves Check X Front casings Clean X Back casings Clean X Exhaust filter Replace X Chiller Clean X Clamping filter Inspect Replace X X Airlock filter Replace X Silicon scraper Replace X Vibrating channel enclosure Clean X Chiller filter Replace X Cabinet filter Replace X Cabinets Clean X Calibration Check X 3D Systems recommends having an additional annual printer service performed by 3D Systems-certified Customer Support Engineer . Contact the 3DSystems hotline . EVERY MONTH MAINTENANCE The pressure and flowrate controls are performed on the control cabinet: A Compressed air pressure B Pinch valve pressure C Gas pressure D Gas flow The unclogging pressure control is performed behind the main cabinet: C A B D Unclogging pressure