    Relion ® 650 series breaker protection req650 2.1 iec product guide.

  • Page 2

    Contents 1. Application..................................................................... 3 2. Available functions..........................................................5 3. Current protection........................................................ 12 4. Voltage protection........................

  • Page 3

    1. Application guid-3f024d79-d031-42dc-b0bc-1f3757b8d3e0 v3 breaker protection req650 provides a standalone solution for applications where synchrocheck controlled closing of the circuit breaker is required, but the integration of the automatic reclosing function into the main line protection ied is...

  • Page 4

    Qb1 qb2 qa1 qb9 qc9 wa1 wa2 req650 b11 – single breaker with single phase tripping 12ai (7i+5u) cc rbrf 50bf 3i>bf ef4 ptoc 51n_67n 4(in>) ef pioc 50n in>> ph pioc 50 3i>> vn mmxu met un vn mmxu met un s simg 63 s siml 71 q cbay 3 control wa2_vt wa1_vt line_ct line_vt smp ptrc 94 1->0 smb rrec 79 5(...

  • Page 5

    2. Available functions back-up protection functions guid-a8d0852f-807f-4442-8730-e44808e194f0 v11 iec 61850 ansi function description breaker req650 (b11) current protection phpioc 50 instantaneous phase overcurrent protection 1 oc4ptoc 51_67 1) four step phase overcurrent protection 1 efpioc 50n in...

  • Page 6

    Control and monitoring functions guid-e3777f16-0b76-4157-a3bf-0b6b978863de v13 iec 61850 ansi function description breaker req650 (b11) control sesrsyn synchrocheck, energizing check and synchronizing 1 smbrrec autorecloser 1 qcbay apparatus control 1 locrem handling of lrswitch positions 1 locremct...

  • Page 7

    Iec 61850 ansi function description breaker req650 (b11) teigapc elapsed time integrator with limit transgression and overflow supervision 12 intcomp comparator for integer inputs 12 realcomp comparator for real inputs 12 monitoring cvmmxn, vmmxu, cmsqi, vmsqi, vnmmxu measurements 6 cmmxu measuremen...

  • Page 8

    Table 1. Total number of instances for basic configurable logic blocks basic configurable logic block total number of instances and 280 gate 40 inv 420 lld 40 or 280 pulsetimer 40 rsmemory 40 srmemory 40 timerset 60 xor 40 1mrk 505 358-ben b breaker protection req650 2.1 iec product version: 2.1 8 a...

  • Page 9

    Communication guid-5f144b53-b9a7-4173-80cf-cd4c84579cb5 v13 iec 61850 ansi function description breaker req650 (b11) station communication lonspa, spa spa communication protocol 1 ade lon communciation protocol 1 horzcomm network variables via lon 1 protocol operation selection between spa and iec 6...

  • Page 10

    Iec 61850 ansi function description breaker req650 (b11) fstaccs, fstaccsna field service tool access via spa protocol over ethernet communication 1 activlog activity logging parameters 1 altrk service tracking 1 singlelcch single ethernet port link status 1 prpstatus dual ethernet port link status ...

  • Page 11

    Basic ied functions guid-c8f0e5d2-e305-4184-9627-f6b5864216ca v10 table 2. Basic ied functions iec 61850 or function name description interrsig self supervision with internal event list selfsupevlst self supervision with internal event list timesynchgen time synchronization module bininput, synchcan...

  • Page 12

    Table 3. Local hmi functions iec 61850 or function name ansi description lhmictrl local hmi signals language local human machine language screen local hmi local human machine screen behavior fnkeyty1–fnkeyty5 fnkeymd1– fnkeymd5 parameter setting function for hmi in pcm600 ledgen general led indicati...

  • Page 13

    An alarm level gives early warning to allow operators to take action well before the line is tripped. Estimated time to trip before operation, and estimated time to reclose after operation are presented. Breaker failure protection ccrbrf m11550-6 v16 breaker failure protection (ccrbrf) ensures a fas...

  • Page 14

    With the neutral point current on a separate input taken from another set of cores on the current transformer. Current circuit supervision (ccsspvc) compares the residual current from a two phase set of current transformer cores with the neutral point current on a separate input taken from another s...

  • Page 15

    Selector mini switch vsgapc semod158756-5 v8 the selector mini switch vsgapc function block is a multipurpose function used for a variety of applications, as a general purpose switch. Vsgapc can be controlled from the menu, from a symbol on the single line diagram (sld) on the local hmi or from bina...

  • Page 16

    A certain level/value, or for creating certain logic. Boolean, integer, floating point, string types of signals are available. One fxdsign function block is included in all ieds. Elapsed time integrator with limit transgression and overflow supervision (teigapc) guid-2d64874a-f266-4251-8eed-e813f405...

  • Page 17

    To all events, which are continuously saved in a -buffer. The local hmi is used to get information about the recordings. The disturbance report files may be uploaded to pcm600 for further analysis using the disturbance handling tool. Event list drprdre m12412-6 v8 continuous event-logging is useful ...

  • Page 18

    Event counter with limit supervison l4ufcnt guid-13157eab-1686-4d2e-85df-ec89768f3572 v5 the 30 limit counter l4ufcnt provides a settable counter with four independent limits where the number of positive and/or negative flanks on the input signal are counted against the setting values for limits. Th...

  • Page 19

    The lhmi is used for setting, monitoring and controlling. 12. Basic ied functions time synchronization m11344-3 v9 the time synchronization function is used to select a common source of absolute time for the synchronization of the ied when it is a part of a protection system. This makes it possible ...

  • Page 20

    Optical ethernet module oem m16073-3 v6 the optical fast-ethernet module is used for fast and interference-free communication of synchrophasor data over ieee c37.118 and/or ieee 1344 protocols. It is also used to connect an ied to the communication buses (like the station bus) that use the iec 61850...

  • Page 21

    See ordering for details about available mounting alternatives. 1mrk 505 358-ben b breaker protection req650 2.1 iec product version: 2.1 abb 21.

  • Page 22

    15. Connection diagrams connection diagrams guid-cf4effa5-3081-4fc7-9a14-ed127c3c0fde v4 the connection diagrams are delivered on the ied connectivity package dvd as part of the product delivery. The latest versions of the connection diagrams can be downloaded from http://www.Abb.Com/substationautom...

  • Page 23

    16. Technical data general ip11376-1 v2 m10993-1 v3 definitions reference value the specified value of an influencing factor to which are referred the characteristics of the equipment nominal range the range of values of an influencing quantity (factor) within which, under specified conditions, the ...

  • Page 24

    Analog inputs ip15842-1 v1 m16988-1 v10 table 4. Trm - energizing quantities, rated values and limits for protection transformer modules quantity rated value nominal range current i r = 1 or 5 a (0.2-40) × i r operative range (0-100) x i r permissive overload 4 × i r cont. 100 × i r for 1 s *) burde...

  • Page 25

    Table 7. Bim - binary input module with enhanced pulse counting capabilities quantity rated value nominal range binary inputs 16 - dc voltage, rl 24/30 v 48/60 v 110/125 v 220/250 v rl ± 20% rl ± 20% rl ± 20% rl ± 20% power consumption 24/30 v 48/60 v 110/125 v 220/250 v max. 0.05 w/input max. 0.1 w...

  • Page 26

    Influencing factors ip15846-1 v1 m16705-1 v10 table 9. Temperature and humidity influence parameter reference value nominal range influence ambient temperature, operate value +20°c -20°c to +55°c 0.02%/°c relative humidity operative range 10-90% 0-95% 10-90% - storage temperature - -40°c to +70°c - ...

  • Page 27

    Table 12. Electromagnetic compatibility test type test values reference standards 1 mhz burst disturbance 2.5 kv iec 60255-26 100 khz slow damped oscillatory wave immunity test 2.5 kv iec 61000-4-18, class iii ring wave immunity test, 100 khz 2-4 kv iec 61000-4-12, class iv surge withstand capabilit...

  • Page 28

    Table 14. Environmental tests test type test value reference standard cold operation test test ad for 16 h at -25°c iec 60068-2-1 cold storage test test ab for 16 h at -40°c iec 60068-2-1 dry heat operation test test bd for 16 h at +70°c iec 60068-2-2 dry heat storage test test bb for 16 h at +85°c ...

  • Page 29

    Current protection m12336-1 v12 table 17. Phpioc function range or value accuracy operate current (5-2500)(5–1200)% of lbase ± 1.0% of i r at i ≤ i r ± 1.0% of i at i > i r reset ratio > 95% at (50–2500)% of ibase > 95% at (5–1200)% of ibase - operate time at 0 to 2 x i set min. = 15 ms40 ms max. = ...

  • Page 30

    M12342-1 v18 table 18. Four-step phase overcurrent protection oc4ptoc function setting range accuracy operate current, step 1-4 (5-2500)% of lbase ± 1.0% of i r at i ≤ i r ± 1.0% of i at i > i r reset ratio > 95% at (50–2500)% of lbase - minimum operate current, step 1-4 (1-10000)% of lbase ± 1.0% o...

  • Page 31

    M15223-1 v16 table 20. Four step residual overcurrent protection ef4ptoc technical data function range or value accuracy operate current, step 1-4 (1-2500)% of ibase ±1.0% of i r at i ≤ i r ±1.0% of i at i > i r reset ratio > 95% at (10-2500)% of ibase - relay characteristic angle (rca) (-180 to 180...

  • Page 32

    Guid-e83ad807-8fe0-4244-a50e-86b9af92469e v5 table 21. Four step negative sequence overcurrent protection ns4ptoc function range or value accuracy operate current, step 1 - 4 (1-2500)% of lbase ±1.0% of i r at i £ i r ±1.0% of i at i > i r reset ratio > 95% at (10-2500)% of ibase - independent time ...

  • Page 33

    M12352-1 v13 table 22. Thermal overload protection, one time constant lcpttr/lfpttr function range or value accuracy reference current (2-400)% of ibase ±1.0% of i r reference temperature (0-300)°c, (0 - 600)°f ± 1.0°c, ±2.0°f operate time: 2 2 2 2 2 ln p trip amb p ref ref i i t t t i i i t t - = -...

  • Page 34

    M12350-1 v11 table 24. Stub protection stbptoc function range or value accuracy operating current (5-2500)% of ibase ± 1.0% of i r at i ≤ i r ± 1.0% of i at i > i r reset ratio > 95% at (50-2500)% of ibase - independent time delay at 0 to 2 x i set (0.000-60.000) s ± 0.2% or ± 30 ms whichever is gre...

  • Page 35

    Voltage protection m13290-1 v14 table 26. Two step undervoltage protection uv2ptuv function range or value accuracy operate voltage, low and high step (1.0–100.0)% of ubase ±0.5% of u r absolute hysteresis (0.0–50.0)% of ubase ±0.5% of u r internal blocking level, step 1 and step 2 (1–50)% of ubase ...

  • Page 36

    M13304-1 v13 table 27. Two step overvoltage protection ov2ptov function range or value accuracy operate voltage, step 1 and 2 (1.0-200.0)% of ubase ±0.5% of u r at u ≤ u r ±0.5% of u at u > u r absolute hysteresis (0.0–50.0)% of ubase ±0.5% of u r at u ≤ u r ±0.5% of u at u > u r inverse time charac...

  • Page 37

    Table 29. Two step residual overvoltage protection rov2ptov function range or value accuracy operate voltage, step 1 - step 2 (1.0-200.0)% of ubase ± 0.5% of u r at u ≤ u r ± 0.5% of u at u > u r maximum up to 130v secondary at 16.7hz definite time delay low step (step 1) at 0 to 1.2 x u set (0.000–...

  • Page 38

    Multipurpose protection m13095-2 v7 1mrk 505 358-ben b breaker protection req650 2.1 iec product version: 2.1 38 abb.

  • Page 39

    Table 31. General current and voltage protection cvgapc function range or value accuracy measuring current input phase1, phase2, phase3, posseq, - negseq, -3*zeroseq, maxph, minph, unbalanceph, phase1-phase2, phase2- phase3, phase3-phase1, maxph-ph, minph-ph, unbalanceph-ph - measuring voltage input...

  • Page 40

    Table 31. General current and voltage protection cvgapc , continued function range or value accuracy independent time delay, undervoltage at 1.2 to 0.8 x u set , step 1 - 2 (0.00 - 6000.00) s ±0.2% or ±35 ms whichever is greater overvoltage: start time at 0.8 to 1.2 x u set min. = 15 ms max. = 30 ms...

  • Page 41

    Semod175176-2 v5 table 32. Rotor earth fault protection function range or value for machines with: • rated field voltage up to 350 v dc • static exciter with rated supply voltage up to 700 v 50/60 hz supply voltage 120 or 230 v 50/60 hz operate earth fault resistance value approx. 1–20 kΩ influence ...

  • Page 42

    Secondary system supervision m12358-1 v8 table 33. Current circuit supervision ccsspvc function range or value accuracy operate current (10-200)% of ibase ±10.0% of i r at i ≤ i r ±10.0% of i at i > i r reset ratio, operate current >90% block current (20-500)% of ibase ±5.0% of i r at i ≤ i r ±5.0% ...

  • Page 43

    Control m12359-1 v13 table 36. Synchronizing, synchrocheck and energizing check sesrsyn function range or value accuracy phase shift, j line - j bus (-180 to 180) degrees - voltage high limit for synchronizing and synchrocheck (50.0-120.0)% of ubase ±0.5% of u r at u ≤ u r ±0.5% of u at u > u r rese...

  • Page 44

    Table 37. Synchronizing, synchrocheck and energizing check sesrsyn function range or value accuracy phase shift, j line - j bus (-180 to 180) degrees - voltage high limit for synchronizing and synchrocheck (10.0-120.0)% of ubase ±0.5% of u r at u ≤ u r ±0.5% of u at u > u r frequency difference limi...

  • Page 45

    M12379-1 v12 table 38. Autorecloser smbrrec function range or value accuracy number of autoreclosing shots 1-5 - autoreclosing open time: shot 1 - t1 1ph shot 1 - t1 2ph shot 1 - t1 3phhs shot 1 - t1 3ph (0.000-120.000) s ±0.2% or ±35 ms whichever is greater shot 2 - t2 3ph shot 3 - t3 3ph shot 4 - ...

  • Page 46

    Table 39. Autorecloser smbrrec function range or value accuracy number of autoreclosing shots 1-5 - autoreclosing open time: shot1 - t1_hs, high speed reclosing without synchrocheck (0.000-20.000) s ±0.2% or ±20 ms whichever is greater shot1 - t1, delayed reclosing (0.000-200.000) s ±0.2% or ±20 ms ...

  • Page 47

    Logic m12380-1 v10 table 40. Tripping logic common 3-phase output smpptrc function range or value accuracy trip action 3-ph, 1/3-ph, 1/2/3-ph - minimum trip pulse length (0.000-60.000) s ±0.2% or ±15 ms whichever is greater 3-pole trip delay (0.020-0.500) s ±0.2% or ±15 ms whichever is greater evolv...

  • Page 48

    Guid-eaa43288-01a5-49cf-bf5b-9abf6dc27d85 v1 table 47. Number of indcalh instances function quantity with cycle time 3 ms 8 ms 100 ms indcalh - 5 - guid-d1179280-1d99-4a66-91ac-b7343dba9f23 v1 table 48. Number of and instances logic block quantity with cycle time 3 ms 8 ms 100 ms and 60 60 160 guid-...

  • Page 49

    Guid-c6c98fe0-f559-45ee-b853-464516775417 v1 table 55. Number of timerset instances logic block quantity with cycle time range or value accuracy 3 ms 8 ms 100 ms timerset 15 15 30 (0.000–90000.000) s ±0.5% ±10 ms guid-0b07f78c-10bd-4070-aff0-6ee36454aa03 v1 table 56. Number of xor instances logic bl...

  • Page 50

    Table 62. Number of teigapc instances function quantity with cycle time 3 ms 8 ms 100 ms teigapc 4 4 4 guid-f5e124e3-0b85-41ac-9830-a2362fd289f2 v1 table 63. Running hour-meter teilgapc function range or value accuracy time limit for alarm supervision, talarm (0 - 99999.9) hours ±0.1% of set value t...

  • Page 51

    Monitoring m12386-1 v14 table 64. Measurements cvmmxn function range or value accuracy frequency (0.95-1.05) x f r ± 2.0 mhz current (0.1-4.0) x i r ± 0.8% of i at 0.1 x i r i 0.2 x i r ± 0.5% of i at 0.2 x i r i 0.5 x i r ± 0.2% of i at 0.5 x i r i 4.0 x i r active power, p (10 to 300) v (0.1-4.0) ...

  • Page 52

    Table 69. Phase-phase voltage measurement vmmxu function range or value accuracy voltage magnitude (10 to 130) v ±0.5% of u phase angle (10 to 130) v ±1.0 degrees at 10 v ≤ u ≤ 110 v ±2.0 degrees at 110 v guid-ed634b6d-9918-464f-b6a4-51b78129b819 v5 table 70. Phase-neutral voltage measurement vnmmxu...

  • Page 53

    Guid-47094054-a828-459b-be6a-d7fa1b317da7 v5 table 74. Voltage sequence measurement vmsqi function range or value accuracy voltage positive sequence, u1 (10 to 300) v ± 0.5% of u at u ≤ 50 v ± 0.2% of u at u > 50 v voltage zero sequence, 3u0 (10 to 300) v ± 0.5% of u at u ≤ 50 v ± 0.2% of u at u > 5...

  • Page 54

    Guid-f034b396-6600-49ef-b0a5-8ed96766a6a0 v6 table 78. Insulation gas monitoring function ssimg function range or value accuracy pressure alarm level 1.00-100.00 ±10.0% of set value pressure lockout level 1.00-100.00 ±10.0% of set value temperature alarm level -40.00-200.00 ±2.5% of set value temper...

  • Page 55

    Table 81. Breaker monitoring sscbr function range or value accuracy alarm level for open and close travel time (0 – 200) ms ±3 ms alarm level for number of operations (0 – 9999) - independent time delay for spring charging time alarm (0.00 – 60.00) s ±0.2% or ±30 ms whichever is greater independent ...

  • Page 56

    M12384-1 v6.1.1 table 86. Disturbance recorder function value buffer capacity maximum number of analog inputs 40 maximum number of binary inputs 128 maximum number of disturbance reports 100 maximum total recording time (3.4 s recording time and maximum number of channels, typical value) 340 seconds...

  • Page 57

    Metering m13404-2 v5 table 88. Pulse-counter logic pcfcnt function setting range accuracy cycle time for report of counter value (1–3600) s - semod153707-2 v4 table 89. Etpmmtr function range or value accuracy energy metering kwh export/import, kvarh export/ import input from mmxu. No extra error at...

  • Page 58

    Station communication m15031-1 v7 m11927-1 v2 table 90. Lon communication protocol function value protocol lon communication speed 1.25 mbit/s m11901-1 v2 table 91. Spa communication protocol function value protocol spa communication speed 300, 1200, 2400, 4800, 9600, 19200 or 38400 bd slave number ...

  • Page 59

    Guid-8651ff22-c007-4d53-b7e3-686a30f37cb6 v4 table 96. Iec 62439-3 edition 1 and edition 2 parallel redundancy protocol function value communication speed 100 base-fx 1mrk 505 358-ben b breaker protection req650 2.1 iec product version: 2.1 abb 59.

  • Page 60

    Hardware ied semod53385-1 v1 m12327-1 v3 table 97. Water and dust protection level according to iec 60529 front ip40 (ip54 with sealing strip) sides, top and bottom ip20 rear side ip20 with screw compression type ip10 with ring lug terminals electrical safety guid-2825b541-dd31-4daf-b5b3-97555f81a1c...

  • Page 61

    Basic ied functions m11963-1 v5 table 101. Self supervision with internal event list data value recording manner continuous, event controlled list size 40 events, first in-first out semod141136-2 v8 table 102. Irig-b quantity rated value number of channels irig-b 1 number of optical channels 1 elect...

  • Page 62

    Inverse characteristic m12388-1 v19 table 103. Ansi inverse time characteristics function range or value accuracy operating characteristic: ( ) 1 p a t b k tdef i æ ö ç ÷ = + × + ç ÷ ç - ÷ è ø equation1249-small v2 en-us reset characteristic: ( ) 2 1 = × - tr t k i equation1250-small v1 en-us i = i ...

  • Page 63

    Table 104. Iec inverse time characteristics function range or value accuracy operating characteristic: ( ) 1 = × - æ ö ç ÷ ç ÷ è ø p a t k i equation1251-small v1 en-us i = i measured /i set 0.10 ≤ k ≤ 3.00 1.5 x i set ≤ i ≤ 20 x i set iec 60255-151, ±2.0% or ±40 ms whichever is greater iec normal i...

  • Page 64

    Semod116978-2 v9 table 106. Inverse time characteristics for undervoltage protection function range or value accuracy type a curve: = æ ö ç ÷ è ø k t u u u equation1431-small v1 en-us u set u = u measured k = (0.05-1.10) in steps of 0.01 ±5.0% or ±45 ms whichever is greater type b curve: 2.0 480 0.0...

  • Page 65

    17. Ordering for pre-configured ied guid-a24820aa-d198-4429-8f9f-def7609b9b85 v2.1.1 guidelines carefully read and follow the set of rules to ensure problem-free order management. Please refer to the available functions table for included application functions. Pcm600 can be used to make changes and...

  • Page 66

    Connection type #7 notes and rules connection type for power supply module compression terminals m ringlug terminals n connection type for input/output modules compression terminals p selection for position #7. P auxiliary power supply #8 notes and rules 24-60 vdc a 90-250 vdc b selection for positi...

  • Page 67

    Remote end communication, dnp serial comm. And time synchronization modules #12 notes and rules slot position (rear view) x312 x313 x302 x303 available slots █ █ █ █ no remote communication board included x x x x irig-b time synchronization module f f f f galvanic rs485 communication module g g g g ...

  • Page 68

    18. Ordering for accessories accessories ip15151-1 v1 test switch semod111888-5 v11 the test system combitest intended for use with the ieds is described in 1mrk 512 001-ben and 1mrk 001024-ca. Please refer to the website: www.Abb.Com/substationautomation for detailed information. Due to the high fl...

  • Page 69

    Rule: specify additional quantity of ied connect cd requested . Quantity: 1mrk 002 290-ad user documentation rule: specify the number of printed manuals requested application manual iec quantity: 1mrk 505 355-uen technical manual iec quantity: 1mrk 505 356-uen commissioning manual iec quantity: 1mrk...

  • Page 70

    Reference information m2175-3 v4 for our reference and statistics we would be pleased to be provided with the following application data: country: end user: station name: voltage level: kv related documents guid-94e8a5ca-be1b-45af-81e7-5a41d34ee112 v3 documents related to req650 document numbers app...

  • Page 71

    71.

  • Page 72

    Contact us for more information please contact: abb ab substation automation products se-721 59 västerås, sweden phone +46 (0) 21 32 50 00 www.Abb.Com/protection-control note: we reserve the right to make technical changes or modify the contents of this document without prior notice. Abb ab does not...