Emh1 wallbox instruction manual with charging cable version: emh1-5x1/5x3-2017-01-10 article no.: 0301501.
Ii contact manufacturer abl sursum bayerische elektrozubehör gmbh & co. Kg albert-büttner-straße 11 91207 lauf / pegnitz germany phone +49(0)9123 188-0 fax +49(0)9123 188-188 web www.Abl.De email info@abl.De support phone +49(0)9123 188-600 email emobility.Support@abl.De.
Iii contents contact ii safety and operating notices 1 safety notices in this manual 1 safety notices on the device 1 general safety information 2 operating instructions / maintenance 2 introduction 4 product description 4 identifying your product variant 5 package contents and unpacking 6 available...
Iv error messages during operation with the vehicle 18 disruptions to the operation of the wallbox and solutions 18 checking the integrated rccb (only for model variants with rccb) 19 taking the device out of operation 20 appendix 22 technical specifications 22 standards & guidelines 24 trademarks 2...
Safety and operating notices 1 safety and operating notices safety notices in this manual this instruction manual contains important information for the installation and safe use of the emh1 – evse 5x1 and evse 5x3 wallboxes it refers to. Please ensure therefore that you read and follow the safety n...
Safety and operating notices 2 in case several users operate the wallbox, the contents of this manual and the safety notices in particular must under all circumstances be passed on to each individual user. General safety information this device represents the current state of technology and fulfils ...
Safety and operating notices 3 • ensure that the rated voltage and rated current of the device comply with the pa- rameters of your local electricity grid and that the rated output is not exceeded dur- ing charging operations. • at all times comply with local safety regulations for the country in wh...
Introduction 4 introduction congratulations on the purchase of your emh1 wallbox by abl! With this wallbox from our “electric mobility home“ series, you have chosen an inno- vative as well as future-proof product that guarantees particularly high operating safety while featuring extremely compact di...
Introduction 5 ants of the evse5x1 and 5x3 series should be installed and taken into operation by a qualified electrical contractor. Your local distributor will be happy to arrange specialist installation for you at your desired location. Identifying your product variant the emh1 series comprises se...
Introduction 6 model power supply model variant evse 503 230 v / 50 hz / 16 a fixed charging cable with type 2 connector, in- ternal residual current circuit breaker, charging output 3.6 kw evse 543 230 v / 50 hz / 16 a fixed charging cable with type 2 connector, inter- nal residual current circuit ...
Introduction 7 available accessories abl sells additional accessories for your emh1 wallbox. For the models of the evse 5x1 and 5x3 series, the following components are available: designation model number quantity mounting pole* for mounting all emh1 wallboxes with or without bracket dimensions: 160...
Installation and power supply connection 8 installation and power supply connection the electrical installation of the emh1 wallbox variants described in this manual must always be carried out by qualified specialist personnel: please contact an electrical contractor or arrange installation at your ...
Installation and power supply connection 9 danger! In case of visible damage to the wallbox occurring during installation or use, the device must be taken out of operation immediately, as this poses a danger to life and limb. In this case, replacement of the wallbox is required! • outdoors the wallb...
Installation and power supply connection 10 drilling the mounting holes using the drilling template proceed as follows to drill the holes using the drilling template: 1. Place the drilling template vertically on the chosen mounting surface: use a spirit level if required. 2. Mark the drill holes usi...
Installation and power supply connection 11 electrical installation of your wallbox the electrical connection of the evse 5x1 / 5x3 to your domestic power supply and taking it into operation must always be carried out by a qualified person or specialist electrical contractor. All local norms and reg...
Installation and power supply connection 12 danger! The above color-coding is not internationally standardized: should the in- dividual wires in the power supply cable be color-coded differently, please immediately contact a qualified electrical contractor! Have the power supply checked and replaced...
Taking into operation and charging procedure 13 taking into operation and charging procedure your wallbox is ready for use immediately after mechanical and electrical installation have been completed. The evse5x1 is equipped with a fixed charging cable with a type 1 charging connector to connect to ...
Taking into operation and charging procedure 14 • ensure that the integrated or external (depending on model variant) fi residual cur- rent circuit breaker (rccb) is switched on. • ensure that the wallbox has been installed according to the instructions in this man- ual: check especially that there ...
Taking into operation and charging procedure 15 charging procedure the evse 5x1 /5x3 is engineered for the fastest possible charge of your vehicle ac- cording to iec 61851-1, mode 3. The actual charging time depends on the battery fitted to your vehicle as well as on the energy currently remaining i...
Taking into operation and charging procedure 16 taking energy consumption readings (model variants with energy meter) various emh1 model variants feature integrated electricity meters with digital displays that inform you about the energy consumption of the wallbox at any time. The en- ergy meter is...
Resolving errors 17 resolving errors your emh1 wallbox is engineered for maximum operational safety and the highest possible charging reliability. The rccb and dc fault current detector (depending on model variant) recognize all internal malfunctions and switch the device off immedi- ately. Should a...
Resolving errors 18 error messages during operation with the vehicle under some circumstances, malfunctions and disruptions may occur that prevent the proper charging of the vehicle according to iec 61851.1, mode 3. The wallbox detects possible errors on the part of the vehicle independently and sho...
Resolving errors 19 to take suitable measures and restore operation in case of malfunction, you must first clearly identify the type of error. The following errors may occur: type of error possible cause suggested solution leds are not functioning the wallbox does not have a power supply. The power ...
Resolving errors 20 please note: the internal dc fault current detector (if present) conducts a self-test before each charging procedure: in case of an error, the respective error sequence will be shown (see page 18). Proceed as follows to test the rccb: 1. Open the cover shield of the wallbox using...
Resolving errors 21 please note: for model variants without rccb, you must switch off the upstream mcb in your domestic power distribution box to temporarily or permanently de- activate the wallbox. Warning! The electrical de-installation of the evse 5x1 / 5x3 must always be car- ried out by a quali...
Appendix 22 appendix technical specifications evse 5x1 series model variant evse 501 evse 511 evse 531 compliance standard iec 61851-1/22 rated voltage 230 v 50 hz rated current 16 a (mcb required onsite) 32 a (mcb required onsite) max. Output 3.6 kw 6.9 kw charging cable type 1, length ca. 5 m circ...
Appendix 23 model variant evse 551 evse 561 compliance standard iec 61851-1/22 rated voltage 230 v 50 hz rated current 16 a (mcb required onsite) max. Output 3.6 kw charging cable type 1, length ca. 5 m circuit-protection devices rccb, type a, 30 ma external rccb required onsite energy meter integra...
Appendix 24 model variant evse 563 evse 573 compliance standard iec 61851-1/22 rated voltage 230/400 v 50 hz 230 v 50 hz rated current 32 a (mcb required onsite) 16 a (mcb required onsite) max. Output 22 kw 3.6 kw charging cable type 2, length ca. 5 m circuit-protection devices external rccb require...
Appendix 25 device safety standards standard description iec 61851-1 ed 2.0:2010 conductive charging systems for electric vehicles – part 1: general requirements iec 61851-22 (69/201/cd) conductive charging systems for electric vehicles – part 22: ac wallbox for electric vehicles din en 61851-1: 201...
Appendix 26 ce certification and declaration of compliance the emh1-evse 5x1 / 5x3 wallbox carries the ce mark. The respective compliance declarations can be obtained from abl sursum bayerische elektrozubehör gmbh & co. Kg on request and are available at www.Abl.De for download. Glossary & definitio...
Appendix 27 drilling template your emh1 wallbox comes with a template (see reduced-size illustration) for drilling the mounting holes in a suitable substrate. Electrical installation of the emh1 model variants described in these instructions must always be left to a qualified electrical contractor w...
Appendix 28 • strictly observe all instructions regarding mounting position and height. You will find the necessary information in section “prerequisites for the mounting site and instal- lation” on page 8. • check the measurements on the drilling template before you mark and drill the holes using t...
Appendix 29 disposal advice the crossed out trash can symbol indicates that electrical and elec- tronic devices including accessories must be disposed of separate from household trash. The materials are recyclable as marked. By re-using, recycling or through other forms of processing obsolete device...
Made in germany albert-büttner-straße 11 d-91207 lauf / pegnitz tel. +49 (0) 9123 188-0 fax +49 (0) 9123 188-188 info@abl.De www.Abl.De abl sursum bayerische elektrozubehör gmbh & co. Kg.