ABL eMH1 Instruction Manual - page 23
reSOlving errOrS
19
To take suitable measures and restore operation in case of malfunction, you must first
clearly identify the type of error.
The following errors may occur:
TYPE OF ERROR POSSIBLE CAUSE
SUGGESTED SOLUTION
LEDs are not
functioning
The Wallbox does
not have a power
supply.
The power supply is interrupted within the
domestic electrical infrastructure: Check
the upstream circuit breaker in the domes-
tic power distribution box.
The internal RCCB of the Wallbox has been
tripped: Check the status of the RCCB and,
if necessary, switch it back on using the
pivot lever.
The indicator LEDs
are faulty
Should the indicator LEDs be faulty, they
must be replaced. In this case, please con-
tact your local distributor.
The electric
vehicle is not
recognized
The charging cable
is not properly
plugged into the ve-
hicle
Remove the recharge plug from the vehicle
and plug it back in: Ensure that the connec-
tor sits properly inside the vehicle socket.
The vehicle is
wrongly configured
Check the vehicle settings and, if neces-
sary, reset them (to factory settings).
The indicator
LEDs show
an error se-
quence
The Wallbox detects
a malfunction
All errors shown by the indicator LEDs
relate to vehicle-based functions (see page
18). The Wallbox reinitiates the charging
procedure every 30 seconds: Should the
error persist, please contact your service
partner for the vehicle.
PLEASE NOTE:
Should there be a fault in the power supply that you cannot resolve
yourself, please contact a qualified electrical contractor.
Should there be a fault in relation to the internal RCCB (if present), please
contact the local distributor from whom you have purchased the Wallbox.
Checking the integrated RCCB
(only for model variants with rccB)
To ensure the continuing safe operation of the Wallbox, you must check the function
of the integrated residual current circuit breaker (RCCB) yourself every 6 months: The