AirPac COOLIT3000 Instruction Manual - page 11
11
Air discharge is on the top of
the unit. The square opening is
the discharge for the evaporator
(cool) air and the round opening
is for the condenser (warm) air
discharge. By using flanges and
duct work (supplied by others)
your COOLIT 3000 can be
made into a versatile stand
alone air conditioning system.
Recommended duct sizes:
8~10” Evaporator
12” Condenser
AIR DISCHARGE
Distributing or
ducting air on
COOLIT 3000
Distributing air
on the COOLIT
3300
When using flexible duct . Flexible duct is convenient and typically
has a high compression ratio, however it can also greatly restrict air
flow when improperly sized or installed. Observe all warnings and
instructions when using flexible duct. If air flow is restricted possible
effects are automatic shut or damage to your system.
CAUTION:
Warm air exhausts from the top of the unit when operating in
cooling mode as an air conditioner. The COOLIT3000 will cool
more efficiently if the warm air is removed from the area.
The COOLIT3300 distributes
cool air through a louvered ple-
num mounted on top the unit.
The horizontal blades can be
manually adjusted. The vertical
blades can be made to oscillate
through the switch above the
control pad.
UNIT OVERVIEW— COOLIT 3300
REAR VIEW
8
Recessed Storage
Compartment for
Power Cord
Condenser Air
Filter
(service access)
Casters
Ceiling Panel
storage behind
service door.