TROUBLE SHOOTING GUIDE
PROBLEM
CAUSE
SOLUTION
Unit does not work
Unit not plugged in.
Plug in power cord.
No power at the
receptacle.
Check fuse or circuit
breaker.
Water tank full.
Empty water tank.
Poor cooling
performance
Wrong function mode
selected.
Set in correct function
mode.
Condenser air exhaust or
intake blocked.
Clear all objects from air
grills, move away from
wall.
Unit operates but is not
cooling
Compressor has not yet
started.
Wait 3 — 5 minutes for
time delay to elapse.
Temperature selection
incorrectly set.
Adjust temperature
setting.
Compressor stops
running after a short time
Voltage is insufficient.
Correct input power.
Unit is plugged into an
extension cord.
Remove extension cord.
Water is leaking
Drain tube clogged.
Remove blockage.
Water tank improperly
seated.
Reposition tank.
Damaged water tank.
Replace tank.
Unit making noise
Unit is not level.
Make sure operating
surface is level.
Water draining into tank. This is normal.
Unit works but is not
cooling the room
enough.
The BTU load in the
room is greater than
28,000 BTU.
Need more cooling. Add
another COOLIT.
Unit making beeping
noise and tank full LED
flickering. Unit still work-
ing
Tank Fault
Unit making beeping
noise and tank full LED
flickering. Fans and com-
pressor not working.
Tank Fault
Close and latch front
door, empty tanks, plug
tank into socket
Pump Fault
Turn off unit. Clear tank
fault and clear pump
fault
Close and latch front
door, empty tanks, plug
tank into socket
17
The first step in preparing the COOLIT3000 for installation is to
run through this check list to ensure you have all the pieces
necessary for your installation.
You have located this manual so you are on the right track!
The enclosed pencil is the only tool you will need to get your
COOLIT3000 up and running. Your shipment consists of one
box:
Each COOLIT3000 and COOLIT3300 series unit box contains:
•
COOLIT3000 or COOLIT3300
•
Two 2.5 Gallon Condensate Tanks
•
Internal Condensate Pump
•
8’ Vinyl Tubing for Condensate Pump
•
COOLIT3000 Series Operation Manual
•
COOLIT3000 Series Warranty Card
•
Plenum with Oscillating Louvers (3300 model)
•
Flexible Duct for Condenser Air (3300 model)
•
Ceiling Panel with duct collar and spring (3300 model)
•
Remote Control (optional)
Before installing and operating your
COOLIT3000 unit please read the
instructions carefully to ensure maximum
benefit from your portable air conditioner.
NOTE:
EQUIPMENT CHECK LIST
COOLIT3000
and 3300
2