Class 1 laser CMOS analog sensor with an analog output. Patent pending.
This guide is designed to help you set up and install the Q4X Analog Sensor. For complete information on programming,
performance, troubleshooting, dimensions, and accessories, please refer to the Instruction Manual at
. Search for p/n 185624 to view the Instruction Manual. Use of this document assumes
familiarity with pertinent industry standards and practices.
For illustration purposes, the threaded barrel model Q4X images are used throughout this document.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry necessary
to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an
energized or de-energized sensor output condition.
Features
1
2
3
Figure 1. Sensor Features—Threaded Barrel
Models
1. Output Indicator (Amber)
2. Display
3. Buttons
1
2
3
Figure 2. Sensor Features—Flush Mount
Models
Display and Indicators
The display is a 4-digit, 7-segment LED. The main screen is the Run Mode screen, which shows the current distance to the
target in millimeters.
Figure 3. Display in Run Mode
1. Stability Indicator (STB = Green)
2. Active TEACH Indicators
•
2-PT = Two-Point TEACH (Amber)
•
1-PT = One-Point TEACH (Amber)
3. Display Value Indicator (MM = Amber)
Output Indicator
•
On—Displayed distance is within the taught analog
output window
•
Off—Displayed distance is outside of the taught
analog output window
Stability Indicator (STB)
•
On—Stable signal within the specified sensing range
•
Flashing—Marginal signal, the target is outside of
the limits of the specified sensing range, or a
multiple peak condition exists
•
Off—No target detected within the specified sensing
range
Active TEACH Indicators (2PT and 1PT)
•
2-PT on—Two-point TEACH mode selected (default)
•
1-PT on—One-point TEACH mode selected
Display Value Indicator (MM)
•
On—Display shows the distance in millimeters
(default)
•
Off—Display shows the analog output value
Q4X Stainless Steel Analog Laser Sensor
Original Document
185623 Rev. D
7 September 2016
185623