CADDX NetworX NX-8 User Manual

Other manuals for NetworX NX-8: User Manual, Application Note, User Manual
Manual is about: System Keypad

Summary of NetworX NX-8

  • Page 1

    User's anual.

  • Page 2: Nx-8 System

    - - fire light is "on" to indicate fire alarm, flashes to indicate a trouble condition with your fire system. Armed light is "on" when armed, "off" when disarmed. Flashes to indicate a previous alarm. Instant light is "on" when there is no entry/exit power light is "on" when ac power is present, fla...

  • Page 3

    Note: some of the features described above may or may not be available for your system. Check with your installation company to find out how your system is programmed..

  • Page 4

    Security system notes installing/service company _ for service call ------------------- central station-------------------- duress code-------- function codes function code controls function this system is d is not d partitioned programmed functions d abort delay (*) d chime d battery test d communi...

  • Page 5

    2 _ _ 23 _ 24 _.

  • Page 6

    2 this manual is furnished to help you understand your security system and become proficient in its operation. All users of your security system should read and follow the instructions and precautions in this booklet. Failure to do so could result in the security system not working properly. This bo...

  • Page 7

    3 table of contents glossary of terms ............................................................................................ 4 abort delay ............................................................................................................. 4 authority level ..............................

  • Page 8

    4 glossary of terms abort delay: an option that allows a delay in reporting to the central station. Authority level: the level of access an individual has when using an alarm panel. Central station: location where alarm data is sent during an alarm report. Chime feature: an option that allows the ke...

  • Page 9

    5 understanding the lights armed light the armed light is "on" when the system is armed. The armed light is "off" when it is disarmed. The armed light will flash when there has been an alarm during the previous arm cycle. Bypass light the bypass light is "on" when any zone in this keypad's partition...

  • Page 10

    6 ready light the ready light is "on" when the system is ready to arm and "flashes" if ready to force arm. The ready light is off when the system is not ready to arm because of a zone(s) being faulted. Stay light the stay light and instant lights are "off" when the entry/exit door(s) are delayed. Th...

  • Page 11

    7 service menu the service light will be "on" if the security system requires service. If the service light is "on", press the [*l key followed by the [2] key to determine the service condition. One or more zone lights will illuminate indicating what service(s) is required. Call your service provide...

  • Page 12

    8 keypad functions arming your system in the "away" mode away is used when the user is away from the premise and wants the interior protected. Listed below are the steps to arm in the away mode: step 1 close all protected doors and windows. • ready light will be on or flashing when all protected zon...

  • Page 13

    9 step 3 • press the [stay] key. • the stay light will illuminate indicating that all interior zones are bypassed. (all interior devices will bypass automatically, giving the user freedom of movement within the interior area.) • the bypass light will illuminate if any zone(s) are bypassed. If any zo...

  • Page 14

    10 disarming the system when you enter the protected area through one of the designated entry/exit doors, the keypad control will sound a solid tone for the duration of the entry delay time, or until you enter a valid code. After entering a valid code, the red armed light will go off and the tone wi...

  • Page 15

    11 unbypassing to manually unbypass zones, perform the bypassing procedure on a zone that is already bypassed. The corresponding light for that zone will go off when unbypassed. Note: all zones will automatically be unbypassed each time the system is disarmed. Turning the door chime on and off the d...

  • Page 16

    12 assigning user code authority levels assign authority levels to users by following the steps below. Assign user codes before assigning authority levels. Step 1 press the [*] key. Step 2 press the [6] key. Step 3 enter a "master arm/disarm code". Note: someone changing the authority of another per...

  • Page 17

    13 step 8 the illuminated numbers indicate each partition where the user has access. To change any of the partitions where the user has access, press numbers corresponding to areas where you want to give the user access or deny access. ( example: if zone light #2 is lit, then the user is assigned ac...

  • Page 18

    14 change partition - optional step 1 press the [*i key. Step 2 press the [1) key. Step 3 press a number key between 1 and 8 to change partitions momentarily. Step 4 if no other key is pressed, it will go back to its standard partition in ten seconds. Step 5 if another key is pressed, the system wil...

  • Page 19: Time

    15 h step 3 press the [7j koy. Step 4 enter the "master code ". Step 5 enter the "hour code" which must be two (2) digits. Note: the clock is a 24-hour clock. Refer to the following table. Step 6 enter the "minutes code" which must be two (2) digits. Example: 7 minutes after would be entered [oj - [...

  • Page 20

    16 e x a m p l e : f o r 1 9 9 7 e n t e r [ 9 j - [ 7 ] ..

  • Page 21

    16 emergency evacuation plans an emergency evacuation .Plan should be established for an actual fire alarm condition. For example, the following steps are recommended by the national fire protection association and can be used as a guide in establishing an evacuation plan for your building. Draw up ...

  • Page 22

    Dul4/_==c=a=dd=x=c=on=tr=o=ls=ln, =c=. == nx-8 user's manual nx8ud97 rev d (11-25-97).