CADDX NetworX NX-8 User Manual - page 11
7
SERVICE MENU
The service light will be "on" if the security system requires service. If the
service light
is "on", press the
[*l
key followed by the
[2]
key to determine the
service condition. One or more zone lights will illuminate indicating what service(s)
is required. Call your service provider immediately for these problems. Below is
a listing of what each light means in a service condition.
LIGHT
PROBLEM
1
SYSTEM FAULT
- Press the [1] key. The zone light(s) that is
illuminated corresponds to the system fault(s) below:
1
Over Current Fault
5
Expander Low Battery
2
Siren Trouble
6
Expander Box Tamper
3
BoxTamper
7
Expander Trouble
4
Expander Power
8
Ground Fault
Note: Faults 1
& 2 are global in nature and will affect all partitions
of a multi-partition system.
Press the [#] key to return to the 1 of 8
service /iahts.
2
ZONE TAMPER
- Press the [2] key and the zone light(s) will illuminate
showing the zone(s) that are tampered. Press the [#] key to return to
the 1 of 8 service Hahts.
3
ZONE LOW BATTERY
- Press the [3] key. The zone light(s) will
illuminate showing which zone(s) has a low battery. This only applies
to wireless zones. Press the [#] key to return to the 1 of 8 service
/iahts.
4
ZONE LOSS OF SUPERVISION
- Press the [4] key and the zone
light(s)
will illuminate showing which zone(s) has loss of supervision.
This only applies to wireless zones. Press [#] key to return to the 1 of
8 service liahts.
5
ZONE TROUBLE
- Press the [5] key and the zone light(s) will illuminate
showing which zone(s) has a trouble condition. Press the f#l kev to
return to the 1 of 8 service liahts.
6
TELEPHONE LINE TROUBLE/LINE CUT
- This light will illuminate
when there is telephone line trouble or the telephone line has been
cut. The service light will remain lit until the telephone trouble clears
and a user code is entered. Note: This fault is global
in
nature and
will affect all oartitions of a multi-oartition svstem.
7
FAILURE TO COMMUNICATE
-This light will illuminate when there is
a failure to communicate between your system and the central station.
Note: This fault is global in nature and will affect all oartitions of
a multi-oartition svstem.
8
LOSS OF SYSTEM TIME
- This light will illuminate when there has been
a loss of power and your system clock needs to be reset. Instructions
are on page 14. Note: This fault is global
in
nature and will affect
all oartitions of a multi-partition system.
To exit the Service Light Mode
- press the
[#]
key.