6.1 REQUIRED EQUIPMENT
Following is a list of test equipment required to perform all of the tests described in this document. It is expected the
user is familiar with the pieces of test equipment listed below. Instructions on how to use the following equipment are
beyond the scope of this document.
Table 3 Required equipment
Type
Model
Notes
Vector signal generator
Agilent E4438C or
equivalent
Recommended option for 50 VDC, 50 W input
protection of RF signal output port. Preprogrammed
with DQPSK data packet and appropriate preamble
reqired by Sprint release. See
APPENDIX F— Program
Signal Generator for DQPSK
.
Vector signal analyzer
Agilent E9010A or
equivalent
10 MHz frequency standard
Standard Research
Systems model FS725
or equivalent
Base frequency adjustments require frequency
standard accuracy to 0.01 ppm or better.
60 dB power attenuator/load
Consists of two pieces with 100 W and 2 W min.
power rating.
Constant voltage DC power
supply
Verify unit supports voltage and current draw required
by unit under test.
Host computer with at least one
Ethernet port and XtermW or
equivalent terminal program
installed
If the host computer’s Ethernet port has not been
configured, then follow the instructions in
APPENDIX
D— Configure the Computer Ethernet Ports to
Communicate with the Transceiver
.
Ethernet cable(s)
Category 5 or better
One Ethernet cable for each computer Ethernet port.
Standard Ethernet cable terminated with RJ-45
connectors.
Clip-on ammeter
Antenna / VSWR test kit
Cable ties as required
Digital volt meter
Network analyzer
Power (Watt) meter
Site tester
7/16" and 1/2" wrenches
7/16" wrench for 1/4" hex nut on grounding stud;
1/2" wrench for 5/16" hex nuts on power terminals.
#2 Phillips head screwdriver
Torque wrench with 100 in.·lb.
capacity
Crimping tool