Menu map
[LANGUAGE]
Default
[Italiano] / [English] / [Français] / [Deutsch] / [Español] / [Portugues euro]/[Portugues bras]
English
[FUNCTIONS]
Default
[AutoClose]
[Disabled]
/
[Turn
on] [Turn
on]
[Maintained Act]
[Disabled] / [Turn on] / [When closing]
[Disabled]
[Obstacle
Det]
[Disabled]
/
[Turn
on]
[Disabled]
[Safety Test]
[Disabled] / [CX] / [CY] / [CZ] / [CX+CY] / [CX+CZ] / [CY+CZ] / [CX+CY+CZ]
[Disabled]
[Pre-flashing]
[Disabled]
/
[Turn
on] [Disabled]
[Ram hit funct]
[Disabled] / [Closing] / [Opening] / [Open-Close]
[Disabled]
[Total
Stop]
[Disabled]
/
[Turn
on]
[Turn
on]
[CX input]
[Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8]
[C1]
[CY input]
[Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8]
[C3]
[CZ input]
[Disabled] / [C1] / [C2] / [C2] / [C4] / [C7] / [C8]
[Disabled]
[Cl.
Thrust] [Disabled]
/
[Turn
on]
[Disabled]
[Lock]
[Disabled]
/
[Closing]
/
[Opening]
/
[Open-Close]
[Disabled]
[Config]
[Time of Run] / [Endstop] / [Slow run] / [Fcap-RallCh] / [ENCODER]
[ENCODER]
[Endstop]
[N.C.
/
N.O.]
[N.C.]
[Cmd 2-7]
[Open-Close] / [Op-Stop-Cl.]
[Open-Close]
[Cmd
2-3P]
[Partial]
/
[Pedestrian]
[Pedestrian]
[Lamp
E]
[Fl.
light]
/
[Courtesy]
/
[Cycle]
[Fl.
light]
[Output
B1-B2]
[Bistable]
/
[Monostable]
[Bistable]
[CRP address]
[1]
⇨ [32]
[CRP baudrate]
[1200] / [2400] / [4800] / [9600] / [19200] / [38400] / [57600] / [115200]
[38400]
[IMP.RUN]
Default
[No.
Motors]
[M1+M2]
/
[M2];
[M1+M2]
[Motor Type]
[FROG-F4024E] / [FROG J] / [FROG-FL] / [AMICO] / [MYTO] / [AXO] / [FAST] / [FERNI]
[FROG-F4024E]
[High speed %]
[20%]
⇨ [100%]
[100%]
[Slow Down Spd. %]
[5%]
⇨ [80%]
[80%]
[Soft
Start] [Turn
on]
/
[Disabled] [Disabled]
[Sens.Amperom]*
[Turn
on]
/
[Disabled] [Turn
on]
[Run Amperom]*
[-
◦+]
[Slow down time]**
[0 s]
⇨ [30 s]
[20 s]
*This function does not appear if [ENCODER] is selected from the [Config] function.
**This function only appears if [Slow run] or [Fcap-RallCh] are selected from the [Config] function.
Meaning of the menu items abbreviations
[Run Amperom]
Gate Run Sensitivity
[Ped. opening]
Partial
Opening
[Maintained Act]
Maintained
Action
[Autoclose] Automatic
Closing
[Config]
Configuration
[Related Func.]
Related
Function
[Imp.Run]
Set
gate
run
[M1 Appr. AP %]
M1 Opening approach as a percentage
[M1 Appr. CH %]
M1 Closing approach as a percentage
[M1 Slow.AP %]
M1 Opening slowdown as a percentage
[M1 Slow.CH %]
M1 Closing slowdown as a percentage
[M2 Appr. AP %]
M2 Opening approach as a percentage
[M2 Appr. CH %]
M2 Closing approach as a percentage
[M2 Slow. AP %]
M2 Opening slowdown as a percentage
[M2 Slow.CH %]
M2 Closing slowdown as a percentage
[Mod Code] Modify
code
[Standby Msg]
Standby
message
[No. Motors]
Number of motors
[Soft Start] Soft
Start
[Slow run Enc]
Opening and closing slow-downs with ENCODER
[Obstacle Det]
Obstacle Detection
[Remove Usr.]
Remove
User
[Op. Delay M1]
M1 Opening Delay
[Cl. Delay M2]
M2 Closing Delay
[Sens.Amperom]
Amperometric
Sensitivity
[Run Amperom]
Run
Sensitivity
[Dec. Amperom]
Slowdown
sensitivity
[Cl. Thrust] Closing
thrust
[Ram hit time]
Ram-jolt
Time
[Preflashing T.]
Preflashing
Time
[Slow down time]
Slow-down
Time
[Lock time] Lock
Time
[A.C.T.]
Automatic
Closing
Time
[Pedestrian ACT]
Pedestrian Automatic Closing Time
[Slow Down Spd.]
Slowdown
Speed
[High speed %]
Gate run speed