ENCODER menu
[ENCODER] menu
[Sensibility]
[Turn on] / [Disabled]
Obstruction detection sensitivity.
[Sensib. Run]
[-
◦+]
Obstruction detection sensitivity during gate run (both opening and closing).
You need to turn on [Sensitivity] in the [ENCODER] menu.
[Sensib. Decel]
[-
◦+]
Obstruction detection sensitivity during slow-down (both opening and closing).
You need to turn on [Sensitivity] in the [ENCODER] menu.
[Slow run Enc]
[ON] / [OFF]
Activating the opening and closing slowdown starting points.
The [ENCODER] menu only appears when [Config] is selected in the [FUNCTIONS] menu.
Gate run setting menu
[Imp. Run]
[No. Motors]
[M1+M2] / [M2]
Setting the number of motors from one to two depending on how many gate- leaves the system has.
[Motor Type]
[FROG-F4024E] / [FROG-J] / [FROG-FL] / [AMICO] / [MYTO] / [AXO] / [FAST] / [FERNI] / [ATI]
Setting the type of operator for the swing gates on the system.
[High speed %]
[20%]
⇨ [100%]
Adjusting the maneuvering speed, calculated as a percentage.
[Slow Down Spd. %]
[5%]
⇨ [80%]
Adjusting the slow-down speed, calculated as a percentage.
[Soft Start]
[Disabled] / [Turn on]
After each opening and closing command, the leaves start at a slowed down speed for a few seconds.
[Sens.Amperom]
[Disabled] / [Turn on]
Obstruction detection sensitivity.
This function does not appear if [Encoder] is set in the [Config] function.
When an obstruction is met, the function intervenes in the following way:
- [Time of Run]
it stops the gate leaves during a maneuver;
- [Endstop] it inverts the gate leaves during a maneuver;
- [Slow run] it inverts the gate leaf movement during a maneuver and stop the movement during a slow down.
- [Fcap-RallCh.] it inverts the gate leaves during a maneuver and stops them only during the closing slow-down.
When the function is disabled, it stops the gate leaves when the maximum voltage threshold is exceeded.
[Run Amperom]
[-
◦+]
Adjusting the amperometric sensitivity.
You need to turn on the [Sens.Amperom] in the [Imp.Run] menu.
[Slow down time]
[OFF]
⇨ [30 s]
Slow-down time of the gate leaves before every endstop. The time can be set to between zero and 30 s.
This function only appears if [Slow run] or [Fcap-RallCh] are set from the [Config] function.
[CRP address]
[1]
⇨ [32]
With systems fitted with several operators and the CRP (Came Remote Protocol) system connection, set an address between 1 and 32 for
each control panel.
[CRP baudrate]
[1200] / [2400] / [4800] / [9600] / [19200] / [38400] / [57600] / [115200]
Setting the communication speed used in the CRP (Came Remote Protocol) connection system.