CAME ZLJ24 Installation Manual - page 4
15 mm~
p.
44
- M
an
u
al
c
od
e:
F
A
0
0
0
3
8
-E
N
F
A
000
3
8
-E
N
v
.
33
- 0
2
/2
0
17 - © C
am
e S
.p.
A
. - T
h
e m
an
u
al
's c
onte
nts m
ay b
e e
d
ite
d at a
ny ti
m
e w
ith
ou
t n
oti
ce
.
slide to rotate
Snap the cover onto the hinges. Close it and secure it using the supplied screws.
After the settings and adjustments, fasten the cover using the supplied screws.
Assemble the pressure hinges.
Fit the hinges into the box (either on the right or left) and fasten them using the supplied screws and washers.
Fasten the control panel in a protected area using suitable screws. anchors and braces.
Drill through the pre-perforated holes and fit the cable gland with corrugated pipes for passing through the electric cables.
Pre-perforated hole diameter: 20 mm.
INSTALLATION
Cable types and minimum thicknesses
Connection
Cable type
Cable length
1
Cable length
10
Cable length
20
Control panel power-supply
FROR CEI 20-22
CEI EN
50267-2-1
2 x 1.5 mm
2
2 x 1.5 mm
2
2 x 2.5 mm
2
Encoder gearmotor power supply*
3 x 1.5 mm
2
3 x 1.5 mm
2
3 x 2.5 mm
2
Power supply to gearmotor**
2 x 1.5 mm
2
2 x 1.5 mm
2
2 x 2.5 mm
2
Flashing light
2 x 0.5 mm
2
Photocell transmitters
2 x 0.5 mm
2
Photocell receivers
4 x 0.5 mm
2
Command and safety device
2 x 0.5 mm
2
Endstop***
3 x 0.5 mm
2
Antenna
RG58
max 10 m
Encoder****
2402C 22AWG
max 30 m
Paired connection or CRP
UTP CAT5
max 1000 m
* AXO ** FROG-A24, F4024, F1024, FROG-A24E, F7024E *** FROG-A24, F4024, F1024 **** FROG-A24E, F7024E, F4024E
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw of the connected
devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual power draw and
distances. For connecting products that are not contemplated in this manual, see the literature accompanying said products