Time settings menu
[TIMING ADJ]
[A.C.T]
[0 s]
⇨ [300 s]
The fi rst automatic closing wait starts when the opening endstop point is reached and can be set to between 0 and 300 s. The automatic
closing does not turn on if any of the safety devices trigger when an obstruction is detected, after a total stop or during a power outage.
[Pedestrian ACT]
[0 s]
⇨ [300 s]
Waiting time of the second M2 leaf in the open position. Once this time elapses, a closing maneuver is automatically performed. The
waiting time can be set to between 0 and 300 seconds.
[Cycle Time]
[10 s]
⇨ [150 s]
Gearmotor working time during opening and closing. The working time can be set to between 10 and 150 seconds.
[Op. Delay M1]
[0 s]
⇨ [10 s]
M1 opening delay in relation to M2 opening after each opening command. The waiting time can be set to between 0 and 10 seconds.
[Cl. Delay M2]
[0 s]
⇨ [60 s]
M2 closing delay in relation to M1 closing after each closing command. The waiting time can be set to between 0 and 60 seconds.
[Prefl ashing T]
[1 s]
⇨ [60 s]
After an opening or closing command, the flashing light connected on 10-E, flashes between one and sixty seconds before starting the
maneuver.
[Lock time]
[1 s]
⇨ [5 s]
Intervention time for the electric lock to release after each opening command. The intervention time can be adjusted to between one second and fi ve seconds.
[Ram hit time]
[1 s]
⇨ [3 s]
The closing and opening jolt thrust time of the geartmotors after each command. The thrust time can be set to between one and three
seconds.
[M1 Slow.AP %]
[1%] ⇨ [60%]
Adjusting the M1 slowdown starting point before the opening endstop.
The slowdown starting point is calculated as a percentage (from 1% to 60% of the complete gate leaf run).
This function only appears if the [Slow run Enc] function is selected in the [ENCODER] menu.
[M1 Slow. CH %]
[1%] ⇨ [60%]
Adjusting the M1 slowdown starting point before the closing endstop.
The slowdown starting point is calculated as a percentage (from 1% to 60% of the complete gate leaf run).
This function only appears if the [Enc. Slwdwn.] function in the [ENCODER] menu.
[M2 Appr. AP %]
[1%] ⇨ [60%]
Adjusting the M2 slowdown starting point before the opening endstop.
The slowdown starting point is calculated as a percentage (from 1% to 60% of the complete gate leaf run).
This function only appears if the [Enc. Slwdwn.] function in the [ENCODER] menu.
[M2 Slow. CH %]
[1%] ⇨ [60%]
Adjusting the M2 slowdown starting point before the closing endstop.
The slowdown starting point is calculated as a percentage (from 1% to 60% of the complete gate leaf run).
This function only appears if the [Enc. Slwdwn.] function in the [ENCODER] menu.
[M1 Appr. CH %]
[1%] ⇨ [15%]
The M1 approach starting point is calculated as a percentage (from 1% to 15% of the complete gate leaf run) before the closing endstop.
[M2 Appr. CH %]
[1%] ⇨ [15%]
The M2 resting starting point is calculated as a percentage (from 1% to 15% of the complete gate-leaf run) before the closing endstop.
[M1 Appr. AP %]
[1%] ⇨ [15%]
The M1 approach starting point is calculated as a percentage (from 1% to 15% of the complete gate-leaf run) before the opening endstop.
[M2 Appr. AP %]
[1%] ⇨ [15%]
The M2 approach starting point is calculated as a percentage (from 1% to 15% of the complete gate-leaf run) before the opening endstop.
[Set Encoder]
Automatic calibration of the gate leaf run (see the CALIBRATING GATE LEAF RUN paragraph).