Canmax CM-520 User Manual - page 163
Enter 163 End
*/$%ENTR* *ZEND*
7. General Configuration Setting
7-2-1-5 Transmission specific symbols Delay Time
Delay time after transmitting specific symbols
*ABBE0*
Configuration Range
Unit
Default Setting
0 ~ 2.5 sec
0.01 sec
0
Procedure:
Example:
(A) Scan “Enter” barcode
(B) Scan “Transmission specific
symbols Delay” barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
If configuration is 0.02 sec, the
parameter value is 0.02 sec / 0.01
sec = 2
7-2-1-6 Transmission Timeout
After sending the information, how long time did not respond will start timeout
*ABCE0*
Procedure:
Example:
(A) Scan “Enter” barcode
(B) Scan Transmission Timeout
barcode
(C) Scan parameters from
Hexadecimal / Decimal table
(D) Scan “OK“ barcode
(E) Scan “End” barcode
If configuration is.2 sec, the
parameter value is 2 sec / 1 sec = 2
Configuration Range
Unit
Default Setting
2 ~ 255 secs
1 sec
3 secs