6.0 CONTROLLING THE MODULE.
6.1 SWITCHING BETWEEN MANUAL TALK & LISTEN AND VOX.
When connected via either the Rapideye or Sensormatic video systems refer to their manuals for controlling the audio, zones
and programming via the central station computer.
When connected to other video equipment or when in a stand-alone mode and after the module has been successfully
activated by, either calling it or answering an alarm call made by the 2244 the operator can control the operation of the
system using a Touch-Tone
phone in the following manner:
Note: The 2244 can still be controlled via Touch-Tone
phone even when connected to a Rapideye or Sensormatic
video system.
DIGIT DESCRIPTION
1
Switch to “TALK” only mode, high volume.
2
Switch to “VOX” mode normal gain and volume.
3
The DTMF digit
3
will:
a) Switch to “LISTEN” only mode at high gain if the 2244 is presently in a mode other than “LISTEN” only, or:
b) Toggle from High gain to Normal gain and visa/versa if the 2244 is already in the “LISTEN” only mode.
7
Reset no-activity hang up timer.
9
Hang up the 2244.
6.2 EXTENDING & DISCONNECTING.
The 2244provides up to nine minutes of two way provided no DTMF digits are pressed. During two way, the module
will generate a "beep" once every minute. Upon the fourth and final minute of two way the module will generate a two
tone "beep bop" warning the central station that there is only one more minute of two way before the module
automatically disconnects. These beeps will be heard at the premise when module is in the "TALK MODE". The central
station will always hear these beeps. To reset the listen in shut down time and cause it to start from zero, press and
release digit
7
at any time during the two way (before the module disconnects). Additionally, anytime a
DTMFcommand is sent the module will automatically reset the timer. The only time the
7
command need actually be
sent is when the module is used in the "LISTEN ONLY" mode for the duration of the call. To shut down the module,
press and release digit
9
at any time. Before the module shuts down it will generate a “beep-beep-bop” tone
indicating it is disconnecting.
6.3 SPEAKER & MIC ZONE CONTROL (MODEL 1410).
The 2244has provisions for selecting zones when utilizing the Model 1410 Four Zone Expansion Module. This
provides the central station with the ability to activate or de-activate any or all speaker and microphone zones.
When the module activates, no zones are active. Zones are toggled ON and OFF. Touch tone command
#
activates
the two digit zone command sequence. For example, to toggle zone one, the command
#01
is sent. All zones
MUST BE TWO DIGITS means the leading
0
is mandatory when selecting zones less than 10!
To turn OFF ALL zones, the command
##
is sent. To turn ALL zones ON, the command
#*
is sent.
CAUTION:
I
F THERE IS A LOUD
,
CONTINUOUS BACKGROUND NOISE
,
SUCH AS A RADIO
,
THE CENTRAL STATION OPERATOR SHOULD
NOT ATTEMPT TO INCREASE THE GAIN OF THE
2244. T
HIS MAY CAUSE THE SYSTEM TO LOOSE THE ABILITY TO RECOGNIZE THE
TONES FROM THE CENTRAL STATION
. I
F THE MODULE
“
LOCKS
-
UP
”
INTO THE
“LISTEN ONLY, HIGH GAIN”
MODE
,
PRESS AND
HOLD THE DIGIT
2
2
2
2
FOR A MINIMUM OF FIVE
(5)
SECONDS
. T
HIS SHOULD UNLOCK THE MODULE
. R
EPEAT IF NECESSARY
.