Eagle Alarm Verification Products 2244 Installation instructions manual - page 15
15
TABLE 8: TOUCH-TONE
COMMAND SUMMARY.
TOUCH -TONE
COMMAND
FUNCTION
1
TALK ONLY
2
VOX MODE
3
LISTEN ONLY, HIGH GAIN or TOGGLE
5n
STORED AUDIO CONTROLS (FUTURE
RELEASE)
7
RESET SHUT DOWN TIMER or IGNORE
SUBSEQUENT ALARM
9
SHUT DOWN MODULE or ALLOW
SUBSEQUENT ALARM TO REPORT
*
ACTIVATE MODULE FROM CALL BACK
MODE (DEFAULT)
TABLE 9: MICROPHONE TOUCH-TONE
COMMAND SUMMARY.
TOUCH -TONE
COMMAND
FUNCTION
#01 – #48
TOGGLE ZONES 1-48
##
ALL MICROPHONES OFF
#*
ALL MICROPHONES ON
6.4 ON BOARD SPEAKER/MIC CONNECTION.
Only one (1) speaker/mic zone exists on the 2244 board itself and it remains active at all times, independent of
which zone is selected.
7.0 OPTIONAL CONNECTIONS.
7.1 MODEL 1410 FOUR ZONE EXPANSION MODULE.
The Model 1410 Four Zone Expansion Module allows the expansion of the 2244 to either four or eight microphone and
speaker zones. Each Model 1410 adds four zones. Up to two 1410’s can be added (in daisy chain fashion). The first
Model 1410 in the chain is connected to the “MODEL 1410” connector (P1) via the cable included with the 1410.
Reference the instructions included with the Model 1410 for further details.
7.2 DIGITALLY STORED AUDIO MODULE.
When available, Eagle’s Digitally Stored Audio Module stores sounds occurring in the premises prior to alarm activation
can be connected to the 2244 Module via the AUX BOARD (P5) connector.