1.2.5 General
The Model 2244 can be expanded from one zone (Model 2244 only) to as many as 48 zones by adding one or more Model
1410 four zone expansion modules.
A VCR via the VCR output can record the audio picked up by Microphone Zone One during standby, along with all the audio
present during an alarm call.
The Model 2244 also features an integrated 12VDC power supply and battery charger. The power supply has an AC indicator,
DC indicator, Reversed Battery polarity protection with indicator, and a Low Battery sensing circuit with indicator and open
collector output.
2.0 REQUIREMENTS.
2.1
POWER.
Operating voltage: 16 VAC 20VA Eagle p/n 115004 Class II Plug-In transformer (user supplied)
2244 Current draw (standby/active): 75 mA / 175 mA
1410 Current draw (active): 10 mA plus 15 mA per active zone
2.2
SYSTEM.
The Eagle 2244requires the following hardware:
1. A local “Emergency Phone” or other means to Trip the 2244.
2. Connections to power (16VAC & Ground) and telephone (Tip & Ring).
3. Model 1410 Four Zone Expansion Module (optional up to 12 maximum)
4. A minimum of one speaker/microphone (Eagle Model 2172F Flush Mount or 2172S Surface Mount)
5. Model 2044 Serial Interface Module if using either a cVideo or Westec DVR
3.0 INSTALLATION.
3.1 INSTALLATION SUMMARY.
1. Mount the Model 2244 into control panel or wiring box.
2. Connect a telephone cord from the telephone interface to the telephone connection (P4) on the 2244.
3. Connect Model 1410 Four Zone Expansion Module to 2244 via included cable.
4. Run cable (standard 4 conductor) from the 1410 Expansion Module to the speaker/mic location(s).
5. Connect cable from the 2172 speaker/mic to the 1410 Four Zone Expansion Module SPK & MIC connectors.
6. Mount one Eagle Model 2172 speaker/microphone, if applicable.
7. Connect additional Model 2172 Speaker/Mic’s, if desired, to the Model 1410 Four Zone Expander.
8. Program
EEPROM.
9. Connect Earth Ground to terminal strip. Connect power & system ground to terminal strip.
10. Connect the “Emergency Phone” to the tip and ring terminals of the emergency phone terminal strip. Connect the
“Emergency Phone” trip (hook) switch to the TRIP and GND terminals.
11. If using the Honeywell Rapideye video systems connect them, via the cable provided, to the DATA IN, CLK and
GND terminals. If using the cVideo or Westec DVR connect to the +12, DATA OUT, CLK & DATA IN terminals.
12. Connect the trip input of the video equipment to the N.O. & COM terminals of the relay terminal strip. To turn off
sirens during the 2-way session connect a 12vdc relay to the RELY & +12 terminals of the relay terminal strip and
run one side of the siren though the relay.
13. If using a VCR to record the audio connect the VCR’s audio input to the VCR and GND terminals.
3.2 WIRING AND PLACEMENT.
3.2.1 TERMINAL STRIP DESCRIPTION - WIRING CONNECTIONS
AC/AC: Connect 16VAC 20VA power to these positions. This powers the module.
EARTH GND: Connect EARTH GROUND to this terminal. This is MANDATORY for proper surge & lightening
protection! Warranty voided without proper EARTH connection.
+ BATT / - BATT: Connect external backup battery here.
(Continued next page.)