DEFAULT: To restore the Default Program Options momentarily short together the two DEFAULT pads.
AUXILLIARY CONNECTOR:
Pin assignments:
Pin 1....... +5 VDC
Pin 2....... GND
Pin 3....... Tones Digitized
Pin 4....... Tones Analog
Pin 5....... Tip
Pin 6....... Ring
Pin 7....... +12 VDC
Pin 8....... /Line Seizure
N.C....... This relay is energized whenever the “Hot Phone”
COM..... is off hook and is used to trip the DVR and/or the
N.O....... Alarm panel.
RELY ... To turn off sirens or bells during “Listen” connect a 12 volt DC relay between RELY & +12
+12 ....... Connect to siren shut off relay and/or Model 2044 Serial Interface Module.
DATA IN........ Connect to Honeywell Rapideye or Model 2044 Serial Interface Module.
CLK............... Connect to Honeywell Rapideye or Model 2044 Serial Interface Module.
DATA OUT.... Connect to Model 2044 Serial Interface Module.
VCR .............. Connect to VCR or other recording device’s Audio Input
GND .............. Connect to Honeywell Rapideye or Model 2044 Serial Interface Module and/or VCR Audio Gnd.
T........... Connect to Tip from the “Hot Phone”
R .......... Connect to Ring from the “Hot Phone”
TRIP..... Connect to the hook switch from the “Hot Phone”
GND ..... Connect to the hook switch from the “Hot Phone”
Phone Jack ...... Connect to Tip & Ring of the “outside” telephone line
MIC ...... Connect to the microphone connection of the Model 2172 Speaker/Microphone Module, no polarity
MIC ...... Connect to the microphone connection of the Model 2172 Speaker/Microphone Module, no polarity
SPK...... Connect to the speaker connection of the Model 2172 Speaker/Microphone Module, no polarity
SPK...... Connect to the speaker connection of the Model 2172 Speaker/Microphone Module, no polarity
Note: The MIC/SPK terminals on the Model 2244 allow the connection of one Model 2172 and are always active
and cannot be switched ON/OFF by the central station operator. Use Model 1410 Four Zone Expansion
Module for switchable zones.