Electrical system
5
Heater wiring
Caution!
Safety instructions for wiring the heater!
The heater is to be connected up electrically
according to the EMC directives.
EMC can be affected if the heater is not connected up
correctly. For this reason, comply with the following
instructions:
• Ensure that the insulation of electrical cables is not
damaged. Avoid: chafing, kinking, jamming or
exposure to heat.
• In waterproof connectors, seal any connector
chambers not in use with filler plugs to ensure they
are dirt-proof and water-proof.
• Electrical connections and ground connections must
be free of corrosion and firmly connected.
• Lubricate connections and ground connections
outside the heater interior with contact grease.
Comply with the following when wiring the heater and the
control element:
• Electrical leads, switchgear and controllers must be
arranged in the vehicle so that they can function
perfectly under normal operating conditions
(e.g.heat exposure, moisture etc.).
• The following cable cross sections are to be used
between the battery and heater. This ensures that
the max. tolerable voltage loss in the cables does
not exceed 0.5 V for 12 V or 1 V for 24 V rated
voltage.
Cable cross sections for a cable length of:
– up to 5 m (plus cable + minus cable) =
cable cross section 4 mm²
– from 5 to 8 m (plus cable + minus cable) =
cable cross section 6 mm²
• If the plus cable is to be connected to the fuse box
(e.g. terminal 30), the vehicle cable from the battery
to the fuse box must be included in rating the overall
cable length and possibly re-dimensioned if
necessary.
• Insulate unused cable ends.