Introduction
1
Statutory regulations
The Federal Road Transport Directorate has issued an
"EC type approval" and an "EMC type approval" for the
heater for installation in motor vehicles and with the
following official type approval marks, noted on the
heater name plate.
HYDRONIC
EC- e1 00 0023
EMC- e1 023971
Regulation!
Directive 2001 / 56 / EU of the European
Parliament and the Council
• Arrangement of the heater
– Parts of the structure and other components near
the heater must be protected from excess heat
exposure and possible contamination from fuel or
oil.
– The heater must not pose a fire hazard even when
it overheats.
This requirement is deemed to be fulfilled when
adequate clearance to all parts is observed during
installation, sufficient ventilation is provided and
fire-proof materials or heat plates are used.
– The heater must not be located in the passenger
compartment in vehicles of class M
1
, M
2
, M
3
and N.
A unit may however be used in a hermetically sealed
housing which also corresponds to the conditions
stated above.
– The factory nameplate or duplicate must be affixed
so that it can still be easily read when the heater
is installed in the vehicle.
– All appropriate precautions must be taken when
arranging the heater to minimise the risk of injuries
to persons or damage to other property.
• Fuel supply
– The fuel intake connection must not be located in
the passenger compartment and must be sealed
with a properly closing lid to prevent any fuel leaks.
– In heaters for liquid fuel where the heater fuel is
separate from the vehicle fuel, the type of fuel and
intake connection must be clearly identified.
– A warning sign is to be fixed to the intake
connection indicating that the heater must be
switched off before refuelling.
• Exhaust system
– The exhaust outlet must be arranged so as to
prevent any penetration of exhaust fumes into the
vehicle interior through the ventilation system,
warm air intakes or open windows.
• Combustion air intake
– The air for the heater combustion chamber must
not be sucked in from the passenger compartment
of the vehicle.
– The air intake must be arranged or protected in
such a way that it cannot be blocked by other
objects.
• Operating status display
– A clearly visible operating display in the user’s
field of vision must indicate when the heater is