Edelbrock 3670 User Manual - page 53
Installation and Setup
53
•
Once all connections are made. Verify that all fuel lines and fittings are tight.
Reconnect vehicle battery.
If you have questions regarding wiring and connections;
refer to the wiring diagrams included in the help section and your vehicle wiring
schematics.
•
Turn key switch to “On” or “Run” position. The fuel pump will turn on and run for
approximately 4 seconds. It will then shut off. Turn key switch off for 15 seconds.
Turn on again and inspect the system for fuel leaks.
•
Set fuel pressure regulator to desired pressure (if regulator is an adjustable type)
while pump is running. Repeat key-off and key-on cycle as many times as required
to purge air, set pressure, and verify fuel system is leak free. Fuel pressure should
be rechecked at idle after engine has been configured.
Do not crank the engine until the system has been configured
using the Setup Wizard in your Pro-Tuner software.