FAAC E145 Quick Manual - page 5
E145
5
732783 - Rev.E
Tr
ansla
tion of the original instruc
tions
ENGLISH
Basic Function
Default
tL
WORK TIME LEARNING OPERATIONS (SET
UP):
Refer to the relative paragraph.
--
St
STATUS OF THE AUTOMATED SYSTEM:
set the selection:
Y
to SAVE and EXIT programming
no
to EXIT programming WITHOUT SAVING
press
F
to confirm; when completed, the
status
of the automated system
will appear on the
display once again:
00
=
CLOSED
01
=
OPEN
02
= Stationary and then “OPENS”
03
= Stationary and then “CLOSES”
04
=
In
“PAUSE”
05
=
Opening
06
=
Closing
07
= FAIL SAFE in progress
08
= Verifying BUS-2easy devices
09
= Pre-flashes and then “OPENS”
10
= Pre-flashes and then “CLOSES”
11
= Emergency open
12
= Emergency close
HP
= Hold position
Y
3.2 ADVANCED PROGRAMMING
Advanced Function
Default
bo
TIME OF MAXIMUM POWER AT START-UP
01
cS
FINAL STROKE WHEN CLOSING (FLUID
HAMMER) (NOT displayed with the
FC
=
1
function)
no
rS
REVERSE STROKE WHEN OPENING (NOT
displayed with the
FA
=
1
function)
no
Od
LEAF OPENING DELAY (only displayed with
the
Mn
=
2
function)
02
r1
LEAF 1 DECELERATION:
The deceleration space can be adjusted as a
percentage of the total travel of leaf 1.
Adjustable from
00
to
99
%, in 1% steps.
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
20
Advanced Function
Default
r2
LEAF 2 DECELERATION (only displayed with
the
Mn
=
2
function):
The deceleration space can be adjusted as a
percentage of the total travel of leaf 2.
Adjustable from
00
to
99
%, in 1% steps.
00
= no deceleration
01
= minimum deceleration space
99
= maximum deceleration space
20
PF
PRE-FLASHING
no
Ph
CLOSING PHOTOCELLS
no
Ad
ADMAP FUNCTION
no
EC
ANTI-CRUSHING SENSITIVITY (only displa-
yed with the
En
=
Y
function):
Varying this function alters the time after which
the board commands the leaves to reverse their
direction in case of an obstacle or to stop if they
are in the contact point search space (refer to
the
rB
function).
The fourth consecutive obstacle detected in the
same direction and position will be defined as
a contact point and the leaf will stop in this
position.
00
= minimum sensitivity (maximum time
before reversal)
10
= maximum sensitivity (minimum time
before reversal)
05
r8
MECHANICAL STOP SEARCH ANGLE (only
displayed with the
En
=
Y
function and
Fc
and
FA
=
no
or =
02
functions):
The mechanical stop search angle within
which the board stops the movement without
reversing if an obstacle is encountered or the
mechanical stop itself can be adjusted.
Can be adjusted from
0.3
to
20
degrees.
0.1 degree steps apply when adjusting between
0.3
and
9.9
degrees.
1 degree steps apply when adjusting between
10
and
20
degrees.
4.0
tA
ADDITIONAL OPERATING TIME only displa-
yed with the
En
=
no
and
Fc
and
FA
=
no
or
02
functions)
03
o1
OUT 1:
Default
00
= always active. Output can be
configured from
00
to
17
.
00
t1
OUT 1 TIMING (only displayed with the
o1
=
03
or
o1
=
14
function)
02
o2
OUT 2:
Default
02
= LED - Refer to the options in
o1
.
02