FAAC E145 Quick Manual - page 6
E145
6
732783 - Rev.E
Tr
ansla
tion of the original instruc
tions
ENGLISH
Advanced Function
Default
t2
OUT 2 TIMING (only displayed with the
o2
=
03
or
o2
=
14
function):
Adjustable like
t1
.
02
AS
MAINTENANCE REQUEST - CYCLE COUNTER
(linked to the subsequent 2 functions)
no
nc
CYCLE PROGRAMMING (THOUSANDS)
00
nd
CYCLE PROGRAMMING (TENS)
00
St
STATUS OF THE AUTOMATED SYSTEM:
Refer to
ST
Basic Function.
Y
3.3 CHECKING THE CONNECTIONS TO
THE MOTOR
M2
(appears if
Mn
=
2
) Function
M2
activates the leaf connected
to motor Mot2 with dead-man enabled.
-
If, however, leaf 1 moves, the power must be disconnected and
the motor connections on terminal board
J2
must be swapped.
-
With a single leaf, if it does not move, you must disconnect the
power and check the connection of the motor to M1 on terminal
board
J2
.
-
If the leaf moves in the wrong direction, disconnect the power
and swap the motor phases on terminal board
J2
.
M1
Function
M1
activates the leaf connected to motor Mot1 with
dead-man enabled.
-
If, however, leaf 2 moves, the power must be disconnected and
the motor connections on terminal board
J2
must be swapped.
-
If the leaf moves in the wrong direction, disconnect the power
and swap the motor phases on terminal board
J2
.
3.4 USEFUL FUNCTIONS TO PROTECT
AGAINST THE RISK OF IMPACT/
CRUSHING ON THE MAIN EDGE
F1
Allows the static thrust force of motor 1 to be adjusted.
NOTE
: For hydraulic operators, set the force value to maximum
and adjust it via the bypass screws.
F2
Allows the static thrust force of motor 2 to be adjusted
NOTE
: For hydraulic operators, set the force value to maximum
and adjust it via the bypass screws.
En
Enables the encoders to be read by the electronic board, thereby
guaranteeing that inversion occurs in the presence of obstacles
(set
En
=
Y
).
Cd
Allows the closing delay of motor 1 to be modified in order to
obtain a phase shift between the two leaves and reducing the
risk of crushing between the two moving leaves.
r1
Allows the space of reduced speed of leaf 1 to be adapted. The
impact at slow speed allows the dynamic force to be reduced.
r2
Allows the space of reduced speed of leaf 2 to be adapted. The
impact at slow speed allows the dynamic force to be reduced.
EC
Allows the obstacle inversion sensitivity to be adjusted.
rB
Allows the space before the mechanical stops in which the
board does not perform inversions to be modified (set a value
between 1 and 49 mm).