5. SIGNALLING ERRORS AND ALARMS
The ERROR LED (
DL13
) will flash to signalling an
alarm.
Alarms
do not compromise operation.
The ERROR LED (
DL13
) will go on steady to signalling
an error.
Errors
stop the operating. Remove the
situation causing the error; it will disappear in the
following cycle.
By simultaneously pressing
+
and
-
the display will
show the number corresponding to the error/alarm
in progress.
Error
Intervention required
01
Board broken
Replace the board
05
Invalid SETUP
Repeat board SETUP
08
BUS-2easy device error
Ensure that no two pairs of devices
have the same address.
09
BUS-2easy output
short-circuit
Check the connections of the con-
nected and entered BUS-2easy
devices
10
Motor 1 limit switch error
Check the limit switch connections
for motor 1
11
Motor 2 limit switch error
Check the limit switch connections
for motor 2
12
BUS-2easy call
Ensure that the BUS devices are
operating correctly and, if neces-
sary, repeat BUS device acquisition
13
FAIL SAFE
Check that the safety devices (pho-
tocells) are operating correctly
14
Configuration error
Check that the board is configu-
red correctly (basic and advanced
programming) and, if necessary,
repeat SETUP
17
Motor 1 encoder fault
Check the connections or replace
motor 1 encoder
18
Motor 2 encoder fault
Check the connections or replace
motor 2 encoder
19
Incorrect memory data
Repeat BUS-2easy device entry
and/or re-program the board
93
High absorption at +24V
Check that absorption by the ac-
cessories connected is within per-
mitted limits
Alarm
Intervention required
20
Obstacle on MOTOR 1
(only with encoder/safe-
ty edge)
Remove any possible obstacle
on leaf 1
21
Obstacle on MOTOR 2
(only with encoder/safe-
ty edge)
Remove any possible obstacle
on leaf 2
25
LOCK 1 output short-
circuit
Remove the cause of the short-
circuit
26
LOCK 2 output short-
circuit
Remove the cause of the short-
circuit
27
Nr. of consecutive ob-
stacles exceeded during
opening
Remove any possible obstacle.
Should the problem persist, repeat
SETUP
28
Nr. of consecutive ob-
stacles exceeded during
closing
Remove any possible obstacle.
Should the problem persist, repeat
SETUP
30
XF radio code memory full
Cancel the radio codes that are not
being used using the PC program
or use an additional DEC/MINIDEC/
RP module
31
Breach alarm
A movement was made with the
automated system in status St =
00 or 01.
Perform an operation cycle.
35
TIMER active and TIMER fun-
ction operating:
TIMER function is operating
40
Service request
Contact the installer for main-
tenance
50
The HOLD POSITION is ope-
rating (active on PC/MAC )
HOLD POSITION function is operating
60
TIMER active and error in
TIMER data
Reload a correct TIMER configura-
tion with the PC/MAC programme
62
Loss of time and date
on the board (only if the
TIMER is operating)
Reload the time and date with the
PC/MAC programme and replace
the BAT1 - CR2032 buffer battery
63
JOLLY TIMER is activated
JOLLY TIMER is enabled by terminal
board J3
64
TIMER DISABLED is ope-
rating
TIMER is disabled by terminal
board J3