FAAC E145 Quick Manual - 6. Operating Logic
E145
9
732783 - Rev.E
Tr
ansla
tion of the original instruc
tions
ENGLISH
6. OPERATING LOGIC
This table summarises the operating logic.
Refer to the complete instructions for a detailed description of each.
LOGIC
Status of the automated
system: stopped
Status of the automated
system: in motion
Status:
photocell action
E
Semi-automatic
An OPEN pulse opens the gate
and the following one closes it
An OPEN pulse stops the gate
when opening and reopens
when the gate is closing
The photocells invert during motion
EP
S emi-automatic,
Step-by-Step
An OPEN pulse opens the gate
and the following one closes it
An OPEN pulse blocks during
motion
The photocells invert during motion
S
Automatic Safety
An OPEN pulse opens the gate
and closes automatically after
the pause time
An OPEN pulse closes the gate
during the pause and inverts
during motion
The closing photocells close the gate once
again during the pause; they memorise clo-
sure when the gate opens and immediately
invert when closing
SA
Automatic Safety
with inversion during
the pause
An OPEN pulse opens the gate
and closes automatically after
the pause time
An OPEN pulse closes during the
pause; has no effect when the
gate opens and inverts when
it closes
The closing photocells reapply the pause
SP
Automatic Step-by-
Step Safety
An OPEN pulse opens the gate
and closes automatically after
the pause time
An OPEN pulse closes the gate
during the pause and blocks
during motion
The closing photocells close the gate once
again during the pause; they memorise clo-
sure when the gate opens and immediately
invert when closing
A1
Automatic 1
An OPEN pulse opens the gate
and closes automatically after
the pause time
An OPEN pulse is ignored when
the gate opens, is reapplied
during the pause and reopens
when the gate closes
The closing photocells close the gate once
again during the pause; they memorise clo-
sure when the gate opens and immediately
invert when closing
A
Automatic
An OPEN pulse opens the gate
and closes automatically after
the pause time
An OPEN pulse is ignored when
the gate opens, is reapplied
during the pause and reopens
when the gate closes
The closing photocells reapply the pause
AP
Automatic, Step-by-
Step
An OPEN pulse opens the gate
and closes automatically after
the pause time
An OPEN pulse blocks when the
gate opens and during the pause
and inverts when it closes
The closing photocells reapply the pause
b
Semi-automatic “b”
(OPEN-B inputs be-
come CLOSE)
Logic with two separate com-
mands: OPEN-A pulse opens;
CLOSE pulse closes
An OPEN-A pulse opens when the
gate closes, a CLOSE pulse closes
when it opens
The photocells invert during motion
bC
Mixed Logic ("b" in
opening; "c" in clo-
sing), OPEN-B inputs
become CLOSE)
Logic with two separate com-
mands: OPEN-A pulse opens;
pressed CLOSE closes
An OPEN-A pulse opens when the
gate closes, a CLOSE pulse closes
when it opens
The photocells invert during motion
C
Dead-man (OPEN-
B inputs become
CLOSE)
Logic with two separate com-
mands: pressed OPEN-A opens;
pressed CLOSE closes
An OPEN-A pulse opens when the
gate closes; a CLOSE pulse closes
when it opens
The photocells invert during motion