Fadini Hindi 880 Instruction Manual

Other manuals for Hindi 880: Installation Manual
Manual is about: Oil-hydraulic actuator to operate swinging gates up to 4 meters

Summary of Hindi 880

  • Page 1

    Gb oil-hydraulic actuator to operate swinging gates up to 4 meters instructions manual pages 13-24 13.

  • Page 2: English

    Application options depending on gate widths 1.0m stroke 150 2.0m 2.5m 4.0m stroke 280 stroke 400 with an electric lock stroke 280 important: the gate post and the gate hinges must be suitable to take the weight and inertia effects generated during the opening and closing operations. = with gate win...

  • Page 3: English

    13 f adini fa dini 1 2 3 4 9 8 7 5 6 10 12 11 14 15 16 17 to suit 400mm 1 - 2 x coded keys opening the sliding lid 2 - cover plug 3 - anodized aluminium cover 4 - internal manual release key (only with the versions hindi 880 locking close & double locking) 5 - rear protection cap 6 - cable gland 7 -...

  • Page 4: English

    10 the electric cable for power supply must dangle loosely during opening and closing movements. Pic. 3 cut to measure. See distance b (page 17). Gate metal reinforcement plate: provide a suitable strengthening plate (optional) to the fixing bracket, depending on the type of gate involved, specially...

  • Page 5: English

    Pic. 5 before fixing hindi 880 to the gate post and gate, power supply the actuator and drive the shaft fully out; then swap the electrical live connections and drive it 5-6 mm in. Important: the ball bearing joint must always be fully tightened by means of the lock nut (pic.9). 12.5µf starting capa...

  • Page 6: English

    Pic. 11 dip-switch on off 1 4 5 6 7 8 2 3 l1 l6 l3 l4 l5 l2 28 26 27 terminals for the connections to pulin 3 push buttons transformer 230v - 24v - + delay time gate closing 0s - 18s motor m1 12.5 µf capacitor motor m2 12.5 µf capacitor - + dwell time 0s - 120s - + motor run time 2s - 100s f1= 5a li...

  • Page 7: English

    Switch setting dip-switch: 1 4 5 6 7 8 2 3 on off 1= on 1 st pair photocells. Stop in opening cycle 2= on radio. No reverse in opening cycle 3= on automatic closing 4= on pre-flasing 5= on radio. Step by step, stop in between 6= on pedestrian opening of one gate, gate in closed position 7= on stroke...

  • Page 8: English

    Common m1 m2 common terminal board - electronic board voltage connections 16 17 18 19 20 21 22 23 24 25 electric motors: once connections to the electric motors have been completed, the three timers as follows are to be set: gate delay on closing, dwell time and motor run time. 8 on: gate delay on o...

  • Page 9: English

    Horizontal for manual release give 1-2 turns anti-clockwise 12 6 3 9 the manual release of hindi 880 system allows to manually operate gates fitted with actuators, locking type. The coded key is supplied with the equipment and must be inserted in the casing lock and turned by 90° anti clockwise in o...

  • Page 10: English

    Right-hand opening hindi 880 installed cut to get a suitable opening for cable leading stud for fixing the cap 95° 90° the two gate stops in open and closed positions are not included ! Installing the gate stop "provided by the installer" pic. 17 gate post line gate stop gate stop in closed position...

  • Page 11: Declaration of Conformity

    Manufacturing company: model: on-the-gate oil-hydraulic operator for swinging gates hindi 880 is to be sold and installed as a comprehensive "automatic system", including the accessories and the components as recommended by the manufacturing company. In observance of the current directives, any auto...

  • Page 12: English

    Power yield 180w (0.25hp) supply voltage 230v frequency 50hz absorbed current 1.3a absorbed power 300w motor revolutions 1 . 350 rev./1' capacitor 12.5µf intermittent service s3 - 25% overall dimensions pic. 20 electric motor technical data "hindi 880" features rear view 11 7 94 12 94 117 117 80 15 ...